File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

김태성

Kim, Taesung
Microfluidics & Nanomechatronics Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 511 -
dc.citation.number 4 -
dc.citation.startPage 501 -
dc.citation.title BIOMEDICAL MICRODEVICES -
dc.citation.volume 9 -
dc.contributor.author Kim, Taesung -
dc.contributor.author Meyhofer, Edgar -
dc.contributor.author Hasselbrink, Ernest F. -
dc.date.accessioned 2023-12-22T09:11:38Z -
dc.date.available 2023-12-22T09:11:38Z -
dc.date.created 2014-09-01 -
dc.date.issued 2007-08 -
dc.description.abstract We have previously demonstrated that shear flow aligns microtubules moving on kinesin-coated microchannels with the flow direction, and statistically analyzed the rate of microtubule alignment under different concentrations of kinesin as well as strengths of shear flow. These data qualitatively support the hypothesis that the alignment results from the leading ends of translocating microtubules bending into the direction of the flow due to viscous drag force. Here, we present a cantilever-beam model that quantitatively shows agreement between this hypothesis and observation. Specifically, the model couples the exact nonlinear solution for cantilever-beam deflection with drag coefficients determined by numerical simulations of microtubules in the presence of shear flow near a wall. Coupled with flexural rigidity results of our previous study (which used electric fields), the established model successfully predicts new experimental data for microtubule bending in response to shear flow, further supporting our hypothesis for the mechanism of microtubule alignment. We expect that the newly-calculated drag coefficients and beambending model may be useful for biophysical studies as well as interpretation of in vivo data and the design of kinesin/microtubule-based devices. -
dc.identifier.bibliographicCitation BIOMEDICAL MICRODEVICES, v.9, no.4, pp.501 - 511 -
dc.identifier.doi 10.1007/s10544-007-9057-3 -
dc.identifier.issn 1387-2176 -
dc.identifier.scopusid 2-s2.0-34548588580 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/5575 -
dc.identifier.url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=34548588580 -
dc.identifier.wosid 000248007500008 -
dc.language 영어 -
dc.publisher SPRINGER -
dc.title Biomolecular motor-driven microtubule translocation in the presence of shear flow: modeling microtubule deflection due to shear -
dc.type Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor biomolecular motor -
dc.subject.keywordAuthor microtubule -
dc.subject.keywordAuthor deflection -
dc.subject.keywordAuthor cantilever model -
dc.subject.keywordAuthor shear flow -
dc.subject.keywordPlus THERMAL FLUCTUATIONS -
dc.subject.keywordPlus SINGLE MICROTUBULE -
dc.subject.keywordPlus FLEXURAL RIGIDITY -
dc.subject.keywordPlus TRANSPORT -
dc.subject.keywordPlus MOVEMENT -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.