DC Field Value Language
dc.citation.endPage 4715 -
dc.citation.number 23 -
dc.citation.startPage 4707 -
dc.citation.title LAB ON A CHIP -
dc.citation.volume 21 -
dc.contributor.author Kim, Chi-Ju -
dc.contributor.author Kim, Jungmin -
dc.contributor.author Sabaté del Río, Jonathan -
dc.contributor.author Ki, Dong Yeob -
dc.contributor.author Kim, Junyoung -
dc.contributor.author Cho, Yoon-Kyoung -
dc.date.accessioned 2023-12-21T15:06:33Z -
dc.date.available 2023-12-21T15:06:33Z -
dc.date.created 2021-11-05 -
dc.date.issued 2021-12 -
dc.description.abstract Platelet function tests, a group of assays that measure the ability of platelets to aggregate and promote clotting in a sample of blood, are performed in various medical fields to assess inherited platelet function disorders and monitor antiplatelet therapies. Light transmission aggregometry (LTA) is considered the gold standard for platelet function assessment. However, the lack of a standardized protocol is a major drawback when applied at the point of care. Moreover, it is a time-consuming and labor-intensive assay that requires a large volume of blood. Here, we describe the design, fabrication, and operation of a centrifugal microfluidic disc that can perform a fully automated LTA assay from a small volume of a whole blood sample (<1 mL), achieving highly reproducible results (3.2% coefficient of variation) within a short period (<25 min). The assays performed with this device yield more precise and accurate results than traditional LTA because of the automation of the reaction steps, minimal human operation, and quick analysis that minimizes the adverse effects of platelet instability. -
dc.identifier.bibliographicCitation LAB ON A CHIP, v.21, no.23, pp.4707 - 4715 -
dc.identifier.doi 10.1039/d1lc00708d -
dc.identifier.issn 1473-0197 -
dc.identifier.scopusid 2-s2.0-85120406006 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/54773 -
dc.identifier.url https://pubs.rsc.org/en/content/articlelanding/2021/lc/d1lc00708d -
dc.identifier.wosid 000716095500001 -
dc.language 영어 -
dc.publisher Royal Society of Chemistry -
dc.title Fully automated light transmission aggregometry on a disc for platelet function tests -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Biochemical Research Methods; Chemistry, Multidisciplinary; Chemistry, Analytical; Nanoscience & Nanotechnology; Instruments & Instrumentation -
dc.relation.journalResearchArea Biochemistry & Molecular Biology; Chemistry; Science & Technology - Other Topics; Instruments & Instrumentation -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -