File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

RuoffRodney Scott

Ruoff, Rodney S.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.number 5 -
dc.citation.startPage 056103 -
dc.citation.title REVIEW OF SCIENTIFIC INSTRUMENTS -
dc.citation.volume 77 -
dc.contributor.author Lu, Shaoning -
dc.contributor.author Guo, Zaoyang -
dc.contributor.author Ding, Weiqiang -
dc.contributor.author Ruoff, Rodney S. -
dc.date.accessioned 2023-12-22T10:06:29Z -
dc.date.available 2023-12-22T10:06:29Z -
dc.date.created 2021-10-19 -
dc.date.issued 2006-05 -
dc.description.abstract A new analytical model is developed for interpreting tensile loading data on "templated carbon nanotubes" (T-CNTs, amorphous carbon nanotubes made by pyrolysis with the channels of nanopores in anodized alumina nanopore arrays) obtained with a microelectromechanical-system (MEMS)-based mechanical testing stage. It is found that the force output from the actuation unit of the testing stage depends on the stiffness of the force sensing beam and the nanostructure being loaded, as well as the power input. A superposition method is used to treat the mechanics of the device structure in the linear elasticity response regime. To our knowledge this is a new approach for solving the mechanical response of MEMS structures with variable force output and of the configuration described herein. An in situ mechanical testing of individual T-CNTs was undertaken in a scanning electron microscope (LEO1525) using a new device fabricated with integrated electrodes for controlled deposition of T-CNTs by electric-field guided assembly in a liquid. The T-CNT was subsequently tensile loaded to the point of fracture. The calculated modulus of the T-CNT using the new model based on the experimentally measured displacement of the moving platform with and without the T-CNT attached falls within the range expected for amorphous carbon. The new model corrects the treatment in a previously presented model [S. Lu , Rev. Sci. Instrum. 75, 2154 (2004)]. -
dc.identifier.bibliographicCitation REVIEW OF SCIENTIFIC INSTRUMENTS, v.77, no.5, pp.056103 -
dc.identifier.doi 10.1063/1.2198789 -
dc.identifier.issn 0034-6748 -
dc.identifier.scopusid 2-s2.0-33744797654 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/54453 -
dc.identifier.url https://aip.scitation.org/doi/10.1063/1.2198789 -
dc.identifier.wosid 000237946000043 -
dc.language 영어 -
dc.publisher AMER INST PHYSICS -
dc.title Analysis of a microelectromechanical system testing stage for tensile loading of nanostructures -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Instruments & Instrumentation; Physics, Applied -
dc.relation.journalResearchArea Instruments & Instrumentation; Physics -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordPlus CARBON NANOTUBES -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.