dc.citation.title DESALINATION -
dc.citation.volume 500 -
dc.contributor.author Lee, Yong-Gu -
dc.contributor.author Kim, Sangwon -
dc.contributor.author Shin, Jaegwan -
dc.contributor.author Rho, Hojung -
dc.contributor.author Kim, Young Mi -
dc.contributor.author Cho, Kyung Hwa -
dc.contributor.author Eom, Heonseop -
dc.contributor.author Oh, Sang-Eun -
dc.contributor.author Cho, Jaeweon -
dc.contributor.author Chon, Kangmin -
dc.date.accessioned 2023-12-21T16:08:56Z -
dc.date.available 2023-12-21T16:08:56Z -
dc.date.created 2021-08-23 -
dc.date.issued 2021-03 -
dc.description.abstract The sequential effects of the cleaning protocols on the desorption of the reverse osmosis (RO) membrane foulants related to the recovery of the membrane surface characteristics were examined through the autopsies of the fouled RO membrane module from the full-scale seawater desalination plant in the Gijang province (Pusan, Republic of Korea). Although the types of cleaning agents were found to be a key factor affecting the desorption of the RO membrane foulants, the sequential cleaning protocol I (SCP I; 0.1 N NaOH -> 0.1 N HCl -> deionized (DI) water) more effectively desorbed both the organic and inorganic foulants from the RO membrane surfaces compared to the sequential cleaning protocol II (SCP II: 0.1 N HCl -> 0.1 N NaOH -> DI water). Moreover, the contact angle and the negative surface zeta potential of the cleaned RO membrane with SCP I were higher than those of the cleaned RO membrane with SCP II. These results demonstrated that the strategic pairing of three different cleaning agents governed the desorption efficiencies of the organic and inorganic foulants and the restoration of the membrane surface features in association with the performances of the RO membranes (i.e., permeate flux and salt rejection). -
dc.identifier.bibliographicCitation DESALINATION, v.500 -
dc.identifier.doi 10.1016/j.desal.2020.114830 -
dc.identifier.issn 0011-9164 -
dc.identifier.scopusid 2-s2.0-85096578267 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/53567 -
dc.identifier.wosid 000606558700005 -
dc.language 영어 -
dc.publisher ELSEVIER -
dc.title Sequential effects of cleaning protocols on desorption of reverse osmosis membrane foulants: Autopsy results from a full-scale desalination plant -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Engineering, Chemical; Water Resources -
dc.relation.journalResearchArea Engineering; Water Resources -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Full-scale seawater desalination plant -
dc.subject.keywordAuthor Membrane autopsy -
dc.subject.keywordAuthor Membrane fouling -
dc.subject.keywordAuthor Reverse osmosis membranes -
dc.subject.keywordAuthor Sequential cleaning effects -
dc.subject.keywordPlus WASTE-WATER RECLAMATION -
dc.subject.keywordPlus ORGANIC FOULANTS -
dc.subject.keywordPlus ULTRAFILTRATION -
dc.subject.keywordPlus MECHANISMS -
dc.subject.keywordPlus STRATEGIES -
dc.subject.keywordPlus RECOVERY -
dc.subject.keywordPlus MATTER -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.