File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

정임두

Jung, Im Doo
Intelligent Manufacturing and Materials Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 888 -
dc.citation.startPage 879 -
dc.citation.title BIO-DESIGN AND MANUFACTURING -
dc.citation.volume 4 -
dc.contributor.author Park, Jong Woong -
dc.contributor.author Shin, Ye Chan -
dc.contributor.author Kang, Hyun Guy -
dc.contributor.author Park, Sangeun -
dc.contributor.author Seo, Eunhyeok -
dc.contributor.author Sung, Hyokyung -
dc.contributor.author Jung, Im Doo -
dc.date.accessioned 2023-12-21T15:06:45Z -
dc.date.available 2023-12-21T15:06:45Z -
dc.date.created 2021-07-27 -
dc.date.issued 2021-12 -
dc.description.abstract Cancer growth in the bone due to its random shape disables bone strength and thus changes its capacity to support body weight or muscles, which can crucially affect the quality of human life in terms of normal walking or daily activities. For successful patient recovery, it is necessary to remove the cancer-affected minimal bone area and quickly replace it with a biocompatible metal implant within less than 2 weeks. An electron beam-melted Ti-6Al-4V implant was designed and applied in a patient to preserve the natural knee joint close to the bone tumor. The developed implant fits the bone defect well, and the independent ambulatory function of the natural knee joint was restored in the patient within six weeks after surgery. A delayed fracture occurred six months after the successful replacement of cancer-affected bone with Ti-6Al-4V implant at the proximal meshed junction of the implant because of a minor downward slip. Microstructural, mechanical, and computational analyses were conducted for the fractured area to find the main reason for the delayed fracture. Our findings pertaining to the mechanical and material investigation can help realize the safe implantation of the three-dimensionally printed titanium implant to preserve the natural joints of patients with massive bone defects of the extremities. -
dc.identifier.bibliographicCitation BIO-DESIGN AND MANUFACTURING, v.4, pp.879 - 888 -
dc.identifier.doi 10.1007/s42242-021-00147-2 -
dc.identifier.issn 2096-5524 -
dc.identifier.scopusid 2-s2.0-85109284771 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/53383 -
dc.identifier.url https://link.springer.com/article/10.1007/s42242-021-00147-2 -
dc.identifier.wosid 000670144400001 -
dc.language 영어 -
dc.publisher SPRINGER HEIDELBERG -
dc.title In vivo analysis of post-joint-preserving surgery fracture of 3D-printed Ti-6Al-4V implant to treat bone cancer -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Engineering, Biomedical -
dc.relation.journalResearchArea Engineering -
dc.type.docType Article; Early Access -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor 3D printing -
dc.subject.keywordAuthor Bone cancer -
dc.subject.keywordAuthor Titanium alloy implant -
dc.subject.keywordAuthor Electron beam melting -
dc.subject.keywordAuthor Fracture analysis -
dc.subject.keywordPlus ENDOPROSTHESES -
dc.subject.keywordPlus OSTEOSARCOMA -
dc.subject.keywordPlus RESECTION -
dc.subject.keywordPlus DESIGN -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.