File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

신세운

Shin, Se-Un
PICTUS Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.conferencePlace US -
dc.citation.conferencePlace San Francisco -
dc.citation.endPage 156 -
dc.citation.startPage 154 -
dc.citation.title IEEE International Solid-State Circuits Conference -
dc.contributor.author Shin, Se-Un -
dc.contributor.author Choi, Minseong -
dc.contributor.author Koh, Seok-Tae -
dc.contributor.author Yang, Yujin -
dc.contributor.author Jung, Seungchul -
dc.contributor.author Sohn, Young-Hoon -
dc.contributor.author Park, Se-Hong -
dc.contributor.author Ju, Yongmin -
dc.contributor.author Jo, Youngsin -
dc.contributor.author Huh, Yeunhee -
dc.contributor.author Choi, Sungwon -
dc.contributor.author Kim, Sang Joon -
dc.contributor.author Cho, Gyu-Hyeong -
dc.date.accessioned 2023-12-19T17:37:10Z -
dc.date.available 2023-12-19T17:37:10Z -
dc.date.created 2021-02-10 -
dc.date.issued 2018-02-13 -
dc.description.abstract Wireless power transfer (WPT) has been widely adopted in various applications, such as biomedical implants and wireless sensors. A conventional voltage-mode receiver (VM-RX) uses a rectifier or a doubler for AC-DC conversion [1,2]. This requires a sufficiently large input power (P,N) inducing a large voltage (VAC) in the LC tank of the receiver (RX) due to the limited voltage conversion efficiency. A subordinate DC-DC converter is also required for voltage regulation or battery charging, which reduces the overall power-conversion efficiency (PCE) due to the 2-stage structure. To overcome these limitations, the resonant current-mode receiver (RCM-RX) has been proposed for direct battery charging [3] and voltage regulation [4,5]. The RCM-RX has two operation phases: a resonance phase (PHre) that accumulates energy in the LC tank during optimal resonant cycles (NOPT) to track the maximum efficiency [3], and a charging phase (PHch) that delivers the energy of the LC tank to the output, when the resonant current (IAC) is at its peak. However, the RCM-RX typically operates at low resonant frequency fRESO (50kHz to 1MHz) because it is challenging to accurately detect the peak timing of IAC due to the intrinsic delay and offset of the comparator used in the peak timing detector. Operating at low fRESO causes the coil size to increase, making a burden on a size-constrained implant. In addition, the RCM-RX has a LC-tank resonance-loss interval PHch, which hinders optimal power transfer from the transmitter (TX) to the RX because the reactive impedance is not cancelled out but appears on the TX side. Because the LC tank and the output are not isolated during PHch, the power-transfer efficiency (PTE) can also be affected by load variation, such as the battery-voltage (VBAT) variation. These problems become worse as NOPT is reduced to lower number. © 2018 IEEE. -
dc.identifier.bibliographicCitation IEEE International Solid-State Circuits Conference, pp.154 - 156 -
dc.identifier.doi 10.1109/ISSCC.2018.8310230 -
dc.identifier.issn 0193-6530 -
dc.identifier.scopusid 2-s2.0-85046424984 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/50015 -
dc.language 영어 -
dc.publisher Institute of Electrical and Electronics Engineers Inc. -
dc.title A 13.56MHz time-interleaved resonant-voltage-mode wireless-power receiver with isolated resonator and quasi-resonant boost converter for implantable systems -
dc.type Conference Paper -
dc.date.conferenceDate 2018-02-11 -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.