File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

이종훈

Lee, Zonghoon
Atomic-Scale Electron Microscopy Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 161 -
dc.citation.number 2 -
dc.citation.startPage 152 -
dc.citation.title CORROSION -
dc.citation.volume 62 -
dc.contributor.author Kus, E -
dc.contributor.author Lee, Zonghoon -
dc.contributor.author Nutt, S -
dc.contributor.author Mansfeld, F -
dc.date.accessioned 2023-12-22T10:08:35Z -
dc.date.available 2023-12-22T10:08:35Z -
dc.date.created 2014-06-09 -
dc.date.issued 2006-02 -
dc.description.abstract Pitting scan (PS) and electrochemical impedance spectroscopy (EIS) techniques were used to evaluate the corrosion behavior of nanocrystalline (NC) samples and conventional Al 5083 (LTNS A95083) in three solutions with different chloride concentrations. The PS obtained in 0.5 N sodium chloride (NaCl) and in 0.5 M sodium sulfate (Na2SO4) + 0.1 N NaCl indicated that pitting should occur in these solutions. These results were confirmed by EIS data that were recorded for up to 25 days. For exposure to 0.5 M Na2SO4 + 0.05 N NaCl the pitting (E-pit) and protection (E-prot) potentials determined after exposure for 2 h suggested that pitting would not occur in this solution. However, the initial impedance spectra were indicative of pitting. Tests carried out after exposure for 2 days and 3 days showed passive behavior, but starting with exposure for 5 days, pitting was again indicated for all three samples. PS performed at the end of the EIS tests suggested that this result was due to the increase in corrosion potential (E-corr) over, the E-prot values recorded at the start of exposure. Evaluation of the samples exposed in the EIS tests showed that the pits were much smaller, but more numerous for Al 5083 after exposure to 0.5 N NaCl. Nitric acid mass loss tests (NAMLT) according to ASTM G 67 indicated that the NC samples were not susceptible to intergranular corrosion. Observation with the SEM showed intergranular corrosion for the conventional. -
dc.identifier.bibliographicCitation CORROSION, v.62, no.2, pp.152 - 161 -
dc.identifier.issn 0010-9312 -
dc.identifier.scopusid 2-s2.0-33645999427 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/4926 -
dc.identifier.url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=33645999427 -
dc.identifier.wosid 000235436300006 -
dc.language 영어 -
dc.publisher NATL ASSOC CORROSION ENG -
dc.title A comparison of the corrosion behavior of nanocrystalline and conventional Al 5083 samples -
dc.type Article -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.