File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

전세영

Chun, Se Young
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.conferencePlace US -
dc.citation.conferencePlace Boston, MA -
dc.citation.endPage 866 -
dc.citation.startPage 863 -
dc.citation.title 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI 2009 -
dc.contributor.author Chun, Se Young -
dc.contributor.author Fessler, Jeffrey A. -
dc.date.accessioned 2023-12-20T04:07:53Z -
dc.date.available 2023-12-20T04:07:53Z -
dc.date.created 2014-12-23 -
dc.date.issued 2009-06-30 -
dc.description.abstract Reducing motion artifacts is an important problem in medical image reconstruction. Using gating to partition data into separate rames can reduce motion artifacts but can increase noise in images reconstructed fromindividual frames. One can pool the frames to reduce noise by using motion-compensated image reconstruction (MCIR) methods. MCIR methods have been studied in many medical imaging modalities to reduce both noise and motion artifacts. However, there has been less analysis of the spatial resolution and noise properties of MCIR methods. This paper analyzes the spatial resolution and noise properties of MCIR methods based on a general parametric motion model. For simplicity we consider the motion to be given. We present a method to choose quadratic spatial regularization parameters to provide predictable resolution properties that are independent of the object and the motion. The noise analysis shows that the estimator variance depends on both the measurement covariance and the Jacobian determinant values of the motion. A 2D PET simulation demonstrates the theoretical results. -
dc.identifier.bibliographicCitation 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI 2009, pp.863 - 866 -
dc.identifier.doi 10.1109/ISBI.2009.5193189 -
dc.identifier.scopusid 2-s2.0-70449356781 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/46838 -
dc.identifier.url https://ieeexplore.ieee.org/document/5193189 -
dc.language 영어 -
dc.publisher IEEE -
dc.title Spatial resolution and noise properties of regularized motion-compensated image reconstruction -
dc.type Conference Paper -
dc.date.conferenceDate 2009-06-30 -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.