File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

전세영

Chun, Se Young
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 6240 -
dc.citation.number 17 -
dc.citation.startPage 6225 -
dc.citation.title PHYSICS IN MEDICINE AND BIOLOGY -
dc.citation.volume 58 -
dc.contributor.author Chun, Se Young -
dc.contributor.author Fessler, Jeffrey A -
dc.contributor.author Dewaraja, Yuni K -
dc.date.accessioned 2023-12-22T03:38:16Z -
dc.date.available 2023-12-22T03:38:16Z -
dc.date.created 2013-09-09 -
dc.date.issued 2013-09 -
dc.description.abstract Quantitative SPECT techniques are important for many applications including internal emitter therapy dosimetry where accurate estimation of total target activity and activity distribution within targets are both potentially important for dose-response evaluations. We investigated non-local means (NLM) post-reconstruction filtering for accurate I-131 SPECT estimation of both total target activity and the 3D activity distribution. We first investigated activity estimation versus number of ordered-subsets expectation-maximization (OSEM) iterations. We performed simulations using the XCAT phantom with tumors containing a uniform and a non-uniform activity distribution, and measured the recovery coefficient (RC) and the root mean squared error (RMSE) to quantify total target activity and activity distribution, respectively. We observed that using more OSEM iterations is essential for accurate estimation of RC, but may or may not improve RMSE. We then investigated various post-reconstruction filtering methods to suppress noise at high iteration while preserving image details so that both RC and RMSE can be improved. Recently, NLM filtering methods have shown promising results for noise reduction. Moreover, NLM methods using high-quality side information can improve image quality further. We investigated several NLM methods with and without CT side information for I-131 SPECT imaging and compared them to conventional Gaussian filtering and to unfiltered methods. We studied four different ways of incorporating CT information in the NLM methods: two known (NLM CT-B and NLM CT-M) and two newly considered (NLM CT-S and NLM CT-H). We also evaluated the robustness of NLM filtering using CT information to erroneous CT. NLM CT-S and NLM CT-H yielded comparable RC values to unfiltered images while substantially reducing RMSE. NLM CT-S achieved -2.7 to 2.6% increase of RC compared to no filtering and NLM CT-H yielded up to 6% decrease in RC while other methods yielded lower RCs than them: Gaussian filtering (up to 11.8% decrease in RC), NLM method without CT (up to 9.5% decrease in RC), and NLM CT-M and NLM CT-B (up to 19.4% decrease in RC). NLM CT-S and NLM CT-H achieved 8.2 to 33.9% and -0.9 to 36% decreased RMSE on tumors compared to no filtering respectively while other methods yielded less reduced or increased RMSE: Gaussian filtering (up to 7.9% increase in RMSE), NLM method without CT (up to 18.3% increase in RMSE), and NLM CT-M and NLM CT-B (up to 31.5% increase in RMSE). NLM CT-S and NLM CT-H also yielded images with tumor shapes that better-matched the true shapes than other methods. All NLM methods using CT information were robust to small misregistration between SPECT and CT, but NLM CT-S and NLM CT-H were more sensitive than NLM CT-M and NLM CT-B to missing CT information. -
dc.identifier.bibliographicCitation PHYSICS IN MEDICINE AND BIOLOGY, v.58, no.17, pp.6225 - 6240 -
dc.identifier.doi 10.1088/0031-9155/58/17/6225 -
dc.identifier.issn 0031-9155 -
dc.identifier.scopusid 2-s2.0-84883186075 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/4132 -
dc.identifier.url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84883186075 -
dc.identifier.wosid 000323517700029 -
dc.language 영어 -
dc.publisher IOP PUBLISHING LTD -
dc.title Post-reconstruction non-local means filtering methods using CT side information for quantitative SPECT -
dc.type Article -
dc.relation.journalWebOfScienceCategory Engineering, Biomedical; Radiology, Nuclear Medicine & Medical Imaging -
dc.relation.journalResearchArea Engineering; Radiology, Nuclear Medicine & Medical Imaging -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.