File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

양준모

Yang, Joon Mo
Medical Device and System Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Water-Immersible MEMS scanning mirror designed for wide-field fast-scanning photoacoustic microscopy

Author(s)
Yao, JunjieHuang, Chih-HsienMartel, CatherineMaslov, Konstantin I.Wang, LidaiYang, Joon MoGao, LiangRandolph, GwendalynZou, JunWang, Lihong V.
Issued Date
2013-02-03
DOI
10.1117/12.2005669
URI
https://scholarworks.unist.ac.kr/handle/201301/37888
Fulltext
https://www.spiedigitallibrary.org/conference-proceedings-of-spie/8581/1/Water-Immersible-MEMS-scanning-mirror-designed-for-wide-field-fast/10.1117/12.2005669.full
Citation
Photons Plus Ultrasound: Imaging and Sensing 2013, v.8581
Abstract
By offering images with high spatial resolution and unique optical absorption contrast, optical-resolution photoacoustic microscopy (OR-PAM) has gained increasing attention in biomedical research. Recent developments in OR-PAM have improved its imaging speed, but have sacrificed either the detection sensitivity or field of view or both. We have developed a wide-field fast-scanning OR-PAM by using a water-immersible MEMS scanning mirror (MEMS-ORPAM). Made of silicon with a gold coating, the MEMS mirror plate can reflect both optical and acoustic beams. Because it uses an electromagnetic driving force, the whole MEMS scanning system can be submerged in water. In MEMS-ORPAM, the optical and acoustic beams are confocally configured and simultaneously steered, which ensures uniform detection sensitivity. A B-scan imaging speed as high as 400 Hz can be achieved over a 3 mm scanning range. A diffraction-limited lateral resolution of 2.4 μm in water and a maximum imaging depth of 1.1 mm in soft tissue have been experimentally determined. Using the system, we imaged the flow dynamics of both red blood cells and carbon particles in a mouse ear in vivo. By using Evans blue dye as the contrast agent, we also imaged the flow dynamics of lymphatic vessels in a mouse tail in vivo. The results show that MEMS-OR-PAM could be a powerful tool for studying highly dynamic and time-sensitive biological phenomena.
Publisher
SPIE

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.