File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

전세영

Chun, Se Young
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.conferencePlace KO -
dc.citation.conferencePlace Seoul; South Korea -
dc.citation.title 2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013 -
dc.contributor.author Chun, Se Young -
dc.contributor.author Dewaraja, Yuni K. -
dc.date.accessioned 2023-12-20T00:37:06Z -
dc.date.available 2023-12-20T00:37:06Z -
dc.date.created 2014-05-19 -
dc.date.issued 2013-11-01 -
dc.description.abstract In our past studies, non-local means (NLM) filtering methods with CT side information for I-131 SPECT estimation have shown promising quantitative results. However, it is challenging to determine optimal filter parameters of these filters without knowing the true image or true dose distribution. Moreover, in SPECT-based dosimetry for I-131 radioimmunotherapy, several parameter optimization steps are necessary since multiple scans are obtained at different count levels to determine time-activity following the tracer and therapy administration. In this paper, we propose practical criteria for choosing filter parameters of NLM filters with CT side information for multiple I-131 SPECT scans without knowing the true activity distribution. We investigate the relationship between quantification and parameters empirically. XCAT simulation results show that our new criteria can determine filtering parameters without knowing the true activity distribution and at different count levels so that the NLM filtering method with CT side information decreased the root mean square error by up to 41% as compared to no filtering while yielding comparable recovery coefficient. -
dc.identifier.bibliographicCitation 2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013 -
dc.identifier.doi 10.1109/NSSMIC.2013.6829276 -
dc.identifier.issn 1095-7863 -
dc.identifier.scopusid 2-s2.0-84904185513 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/35619 -
dc.identifier.url https://ieeexplore.ieee.org/document/6829276 -
dc.language 영어 -
dc.publisher IEEE -
dc.title Investigation on Parameter Selection of Non-Local Means Filters Using CT Side Information for Multiple I-131 SPECT Scans -
dc.type Conference Paper -
dc.date.conferenceDate 2013-10-27 -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.