File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

방인철

Bang, In Cheol
Nuclear Thermal Hydraulics and Reactor Safety Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 113 -
dc.citation.startPage 105 -
dc.citation.title INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER -
dc.citation.volume 60 -
dc.contributor.author Lee, Seung Won -
dc.contributor.author Kim, Seong Man -
dc.contributor.author Park, Seong Dae -
dc.contributor.author Bang, In Cheol -
dc.date.accessioned 2023-12-22T04:07:23Z -
dc.date.available 2023-12-22T04:07:23Z -
dc.date.created 2013-07-05 -
dc.date.issued 2013-05 -
dc.description.abstract Following the March 2011 earthquake, the nuclear power plants in Japan were affected, and emergency systems were activated. The earthquake caused a tsunami, which hit the east coast of Japan, and caused a loss of all on-site and off-site power at the Fukushima Daiichi, leaving it without any emergency power. In this situation, freshwater and seawater were used by helicopter, fire truck, and concrete pump truck to remove heat. To investigate the effect of 35 parts per thousand sea salt solution on reflood heat transfer in a long vertical tube (1600 mm in the heating length), quenching experiments were conducted. We have observed a more enhanced cooling performance in the case of the sea salt solution reflood. Consequently, the cooling performance is enhanced more than nearly 10 s for sea salt solution. The enhancing cause of the cooling performance after the quenching experiments using the sea salt solution were investigated through the macroscopic observation, scanning electron microscopy (SEM), contact angles and SEM-energy dispersive X-ray spectroscopy (EDS) of the inner surface of the test section. The cause of the cooling performance enhancement for the sea salt solution is not related to the enhanced wettability of the liquid film on the heater surface due to the deposition of sea salts but the top quenching by earlier condensation of vapor during sea salt solution reflood. -
dc.identifier.bibliographicCitation INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, v.60, pp.105 - 113 -
dc.identifier.doi 10.1016/j.ijheatmasstransfer.2012.12.046 -
dc.identifier.issn 0017-9310 -
dc.identifier.scopusid 2-s2.0-84873829640 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/3475 -
dc.identifier.url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84873829640 -
dc.identifier.wosid 000317534500014 -
dc.language 영어 -
dc.publisher PERGAMON-ELSEVIER SCIENCE LTD -
dc.title Study on the cooling performance of sea salt solution during reflood heat transfer in a long vertical tube -
dc.type Article -
dc.relation.journalWebOfScienceCategory Thermodynamics; Engineering, Mechanical; Mechanics -
dc.relation.journalResearchArea Thermodynamics; Engineering; Mechanics -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Fukushima accident -
dc.subject.keywordAuthor Reflood -
dc.subject.keywordAuthor Sea salt solution -
dc.subject.keywordAuthor Cooling performance -
dc.subject.keywordAuthor Seawater -
dc.subject.keywordPlus SIC NANOFLUIDS -
dc.subject.keywordPlus NANOPARTICLES -
dc.subject.keywordPlus SURFACE -
dc.subject.keywordPlus ALUMINA -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.