Ultrasensitive detection of hydrogen peroxide and dopamine using copolymer-grafted metal-organic framework based electrochemical sensor

Cited 0 times inthomson ciCited 0 times inthomson ci
Title
Ultrasensitive detection of hydrogen peroxide and dopamine using copolymer-grafted metal-organic framework based electrochemical sensor
Author
Hira, Shamim AhmedNallal, MuthuchamyRajendran, KarkuzhaliSong, SehwanPark, SungkyunLee, Jae-MyungJoo, Sang HoonPark, Kang Hyun
Issue Date
2020-06
Publisher
ELSEVIER
Citation
ANALYTICA CHIMICA ACTA, v.1118, pp.26 - 35
Abstract
We reported the synthesis of a copolymer- and metal-organic framework-based electrochemical sensor, UiO-66-NH2@P(ANI-co-ANA) using the polymerization method for the highly sensitive and selective detection of hydrogen peroxide (H2O2) and dopamine (DA). The as-synthesized material was characterized via Fourier transform infrared spectroscopy, X-ray diffraction analysis, scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and thermogravimetric analysis. The electrochemical characteristics of the proposed sensor were evaluated via impedance spectroscopy and cyclic voltammetry (CV). The electrochemical oxidation of DA and the reduction of H2O2 were determined via CV, square-wave voltammetry, and chronoamperometric techniques. The fabricated sensor exhibited a wide linear range of 25-500 mu M, with a sensitivity of 1396.1 mu A mu M-1 cm(-2) and a limit of detection of 0.6 mM, for the electrochemical reduction of H2O2. Additionally, it exhibited a wide linear range of 10-110 mM, with a sensitivity of 1110.2 mu A mu M(-1)cm(-2) and a limit of detection of 0.3 mu M, for the electrochemical detection of DA. The practical utility of the fabricated sensor was evaluated via the detection of H2O2 in milk samples and DA in human urine samples. (C) 2020 Elsevier B.V. All rights reserved.
URI
https://scholarworks.unist.ac.kr/handle/201301/32055
URL
https://www.sciencedirect.com/science/article/pii/S0003267020304542
DOI
10.1016/j.aca.2020.04.043
ISSN
0003-2670
Appears in Collections:
PHY_Journal Papers
Files in This Item:
There are no files associated with this item.

find_unist can give you direct access to the published full text of this article. (UNISTARs only)

Show full item record

qrcode

  • mendeley

    citeulike

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

MENU