DC Field Value Language
dc.citation.startPage 108052 -
dc.citation.title COMPOSITES PART B-ENGINEERING -
dc.citation.volume 194 -
dc.contributor.author Lee, Sooyoung -
dc.contributor.author Jo, Eonyeon -
dc.contributor.author Ji, Wooseok -
dc.date.accessioned 2023-12-21T17:11:52Z -
dc.date.available 2023-12-21T17:11:52Z -
dc.date.created 2020-05-07 -
dc.date.issued 2020-08 -
dc.description.abstract In the present study, the digital volume correlation (DVC) technique is used to study the deformation behavior occurring inside a carbon fibre-reinforced epoxy composite. While a tensile test on a symmetric angle-ply laminated composite specimen is being performed, X-ray images are recorded using synchrotron radiation. The radiographs are processed to reconstruct 3D mu CT images. The reconstruction process utilizes a filtered back-projection (FBP) algorithm combined with a phase retrieval method to enhance the contrast of the CT images. Phase contrast is crucial since the natural microstructural pattern is analogous to a speckle pattern for digital image correlation (DIC) analysis. A slight misalignment of the specimen, typically negligible at the macroscopic scale, is corrected in the CT images prior to the DVC analysis. The accuracy of the DVC results is improved by implementing a sub-voxel registration approach to achieve a resolution less than one pixel. The DVC results are compared with finite element analysis (FEA) results. Although the overall results agree well with the FEA results, few subvolumes are prone to fail to find their correct pairs within DVC volumes. Raw 2D tomograms are individually examined and compared to show that a high correlation coefficient value does not always guarantee a correct match. Detailed discussions about the misleading correlations are provided and thereby the validations and limitations of the DVC (and DIC) technique are addressed. -
dc.identifier.bibliographicCitation COMPOSITES PART B-ENGINEERING, v.194, pp.108052 -
dc.identifier.doi 10.1016/j.compositesb.2020.108052 -
dc.identifier.issn 1359-8368 -
dc.identifier.scopusid 2-s2.0-85084188694 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/32053 -
dc.identifier.url https://www.sciencedirect.com/science/article/pii/S1359836819356215 -
dc.identifier.wosid 000535933900013 -
dc.language 영어 -
dc.publisher ELSEVIER SCI LTD -
dc.title Digital volume correlation technique for characterizing subsurface deformation behavior of a laminated composite -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Engineering, Multidisciplinary; Materials Science, Composites -
dc.relation.journalResearchArea Engineering; Materials Science -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordPlus X-RAY TOMOGRAPHY -
dc.subject.keywordPlus REGISTRATION ALGORITHMS -
dc.subject.keywordPlus STRAIN-MEASUREMENTS -
dc.subject.keywordPlus FIELD-MEASUREMENTS -
dc.subject.keywordPlus IMAGE -
dc.subject.keywordPlus DAMAGE -
dc.subject.keywordPlus PHASE -
dc.subject.keywordPlus 3D -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.