There are no files associated with this item.
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.citation.endPage | 2140 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 2133 | - |
dc.citation.title | ANALYTICAL CHEMISTRY | - |
dc.citation.volume | 84 | - |
dc.contributor.author | Park, Jiwoon | - |
dc.contributor.author | Sunkara, Vijaya | - |
dc.contributor.author | Kim, Tae-Hyeong | - |
dc.contributor.author | Hwang, Hyundoo | - |
dc.contributor.author | Cho, Yoon-Kyoung | - |
dc.date.accessioned | 2023-12-22T05:17:02Z | - |
dc.date.available | 2023-12-22T05:17:02Z | - |
dc.date.created | 2013-06-14 | - |
dc.date.issued | 2012-03 | - |
dc.description.abstract | This paper presents a cost-effective, rapid, and fully automated lab-on-a-disc for simultaneous detection of multiple protein biomarkers in raw samples such as whole blood or whole saliva. For the diagnosis of cardiovascular disease, here, a novel centrifugal microfluidic layout was designed to conduct the simultaneous detection of high sensitivity C-reactive protein, cardiac troponin I, and N-terminal pro-B type natriuretic peptide based on a bead-based sandwich type enzyme-linked immunosorbent assay (ELISA). Three reaction chambers are initially interconnected for the common processes such as sample injection, incubation, and washing and then isolated on-demand for the independent processes such as substrate incubation and final detection. The assay performances such as the limit of detection and the dynamic range were comparable with those of the conventional ELISA despite the significant reduction of the minimum sample volume (200 mu L), the amount of washing buffer (700 mu L), and the total process time (20 min). | - |
dc.identifier.bibliographicCitation | ANALYTICAL CHEMISTRY, v.84, no.5, pp.2133 - 2140 | - |
dc.identifier.doi | 10.1021/ac203163u | - |
dc.identifier.issn | 0003-2700 | - |
dc.identifier.scopusid | 2-s2.0-84863272314 | - |
dc.identifier.uri | https://scholarworks.unist.ac.kr/handle/201301/3203 | - |
dc.identifier.url | http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84863272314 | - |
dc.identifier.wosid | 000301021400008 | - |
dc.language | 영어 | - |
dc.publisher | AMER CHEMICAL SOC | - |
dc.title | Lab-on-a-Disc for Fully Integrated Multiplex Immunoassays | - |
dc.type | Article | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordPlus | C-REACTIVE PROTEIN | - |
dc.subject.keywordPlus | MICROFLUIDIC DEVICE | - |
dc.subject.keywordPlus | IMMUNOSORBENT-ASSAY | - |
dc.subject.keywordPlus | DIAGNOSTICS | - |
dc.subject.keywordPlus | BIOMARKERS | - |
dc.subject.keywordPlus | PLATFORMS | - |
dc.subject.keywordPlus | BIOSENSOR | - |
dc.subject.keywordPlus | PEPTIDE | - |
dc.subject.keywordPlus | ARRAYS | - |
dc.subject.keywordPlus | SENSOR | - |
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.