File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

이덕중

Lee, Deokjung
Computational Reactor physics & Experiment Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 168 -
dc.citation.startPage 154 -
dc.citation.title ANNALS OF NUCLEAR ENERGY -
dc.citation.volume 133 -
dc.contributor.author Jeong, Eun -
dc.contributor.author Park, Jinsu -
dc.contributor.author Lee, Hyun Chul -
dc.contributor.author Zhang, Peng -
dc.contributor.author Yu, Jiankai -
dc.contributor.author Lemaire, Matthieu -
dc.contributor.author Choi, Sooyoung -
dc.contributor.author Lee, Deokjung -
dc.date.accessioned 2023-12-21T18:36:46Z -
dc.date.available 2023-12-21T18:36:46Z -
dc.date.created 2019-06-10 -
dc.date.issued 2019-11 -
dc.description.abstract This paper presents the verification of the DeCART2D/CAPP code system for the Very High Temperature Gas-Cooled Reactor (VHTR) analysis with the Prismatic Modular Reactor 200 (PMR-200) benchmark. The McCARD Monte Carlo (MC) code is used to obtain the reference solution. The verification has been performed for the effective multiplication factor (k eff ) and reactivity coefficients at the levels of fuel compact, fuel block, and full core. Furthermore, the verification of the depletion calculation has been conducted for the fuel block and the verification for the power distribution has been performed at the levels of fuel block, two-dimensional (2D) and three-dimensional (3D) full core. The verification results of DeCART2D, CAPP, and DeCART2D/CAPP are compared systematically against the reference McCARD solutions to demonstrate the VHTR modeling capability and accuracy of the codes. It was successfully shown that the k eff errors of the DeCART2D/CAPP code system are smaller than ∼510 pcm, the isothermal temperature coefficient (ITC) errors are smaller than ∼0.66 pcm/K, and the power distribution errors are smaller than 2.80%. It was also shown that the maximum k eff errors of DeCART2D fuel block depletion calculations are smaller than ∼460 pcm. -
dc.identifier.bibliographicCitation ANNALS OF NUCLEAR ENERGY, v.133, pp.154 - 168 -
dc.identifier.doi 10.1016/j.anucene.2019.05.002 -
dc.identifier.issn 0306-4549 -
dc.identifier.scopusid 2-s2.0-85065743087 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/27510 -
dc.identifier.url https://www.sciencedirect.com/science/article/pii/S0306454919302452?via%3Dihub -
dc.identifier.wosid 000484649800016 -
dc.language 영어 -
dc.publisher Elsevier Ltd -
dc.title Verification of DeCART2D/CAPP code system for VHTR analysis with PMR-200 benchmark -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Nuclear Science & Technology -
dc.relation.journalResearchArea Nuclear Science & Technology -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor DeCART2D/CAPP -
dc.subject.keywordAuthor Generation-IV reactor -
dc.subject.keywordAuthor McCARD -
dc.subject.keywordAuthor PMR-200 -
dc.subject.keywordAuthor VHTR -
dc.subject.keywordPlus Codes (symbols) -
dc.subject.keywordPlus Errors -
dc.subject.keywordPlus Fuels -
dc.subject.keywordPlus Gas cooled reactors -
dc.subject.keywordPlus Reactor cores -
dc.subject.keywordPlus Temperature -
dc.subject.keywordPlus DeCART2D/CAPP -
dc.subject.keywordPlus Generation IV reactors -
dc.subject.keywordPlus McCARD -
dc.subject.keywordPlus PMR-200 -
dc.subject.keywordPlus VHTR -
dc.subject.keywordPlus High temperature reactors -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.