File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

이영주

Lee, Young-Joo
Structural Reliability and Disaster Risk Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 9 -
dc.citation.startPage 1 -
dc.citation.title MATHEMATICAL PROBLEMS IN ENGINEERING -
dc.citation.volume 2019 -
dc.contributor.author Jeong, Seunghoo -
dc.contributor.author Lee, Young-Joo -
dc.contributor.author Sim, Sung-Han -
dc.date.accessioned 2023-12-21T19:09:51Z -
dc.date.available 2023-12-21T19:09:51Z -
dc.date.created 2019-06-03 -
dc.date.issued 2019-05 -
dc.description.abstract As the construction of long-span bridges such as cable-stayed bridges increases worldwide, maintaining bridge serviceability and operability has become an important issue in civil engineering. The stay cable is a principal component of cable-stayed bridges and is generally lightly damped and intrinsically vulnerable to vibration. Excessive vibrations in stay cables can potentially cause long-term fatigue accumulation and serviceability issues. Previous studies have mainly focused on the mitigation of cable vibration within an acceptable operational level, while little attention has been paid to the quantitative assessment of serviceability enhancement provided by vibration control. This study accordingly proposed and evaluated a serviceability assessment method for stay cables equipped with vibration control. Cable serviceability failure was defined according to the range of acceptable cable responses provided in most bridge design codes. The cable serviceability failure probability was then determined by means of the first-passage problem using VanMarcke’s approximation. The proposed approach effectively allows the probability of serviceability failure to be calculated depending on the properties of any installed vibration control method. To demonstrate the proposed method, the stay cables of the Second Jindo Bridge in South Korea were evaluated and the analysis results accurately reflected cable behavior during a known wind event and show that the appropriate selection of vibration control method and properties can effectively reduce the probability of serviceability failure. -
dc.identifier.bibliographicCitation MATHEMATICAL PROBLEMS IN ENGINEERING, v.2019, pp.1 - 9 -
dc.identifier.doi 10.1155/2019/4138279 -
dc.identifier.issn 1024-123X -
dc.identifier.scopusid 2-s2.0-85066017468 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/26714 -
dc.identifier.url https://www.hindawi.com/journals/mpe/2019/4138279/ -
dc.identifier.wosid 000468516700001 -
dc.language 영어 -
dc.publisher Hindawi Publishing Corporation -
dc.title Serviceability Assessment Method of Stay Cables with Vibration Control Using First-Passage Probability -
dc.type Article -
dc.description.isOpenAccess TRUE -
dc.relation.journalWebOfScienceCategory Engineering, Multidisciplinary; Mathematics, Interdisciplinary Applications -
dc.relation.journalResearchArea Engineering; Mathematics -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.