File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 197 -
dc.citation.number 1 -
dc.citation.startPage 191 -
dc.citation.title SAINS MALAYSIANA -
dc.citation.volume 48 -
dc.contributor.author Trinh Thi Tu Anh -
dc.contributor.author Pham Dang Quyet -
dc.contributor.author Mai Nguyen Trong Nhan -
dc.contributor.author Pham Ngoc Son -
dc.date.accessioned 2023-12-21T19:40:59Z -
dc.date.available 2023-12-21T19:40:59Z -
dc.date.created 2019-03-14 -
dc.date.issued 2019-01 -
dc.description.abstract Exposure dose rate to the tumor and surrounding cells during neutron beam irradiation in Boron Neutron Capture Therapy (BNCT) comes not only from heavy charged particles produced from the B-10(n,alpha)Li-7 nuclear reaction, but also from neutron-induced reactions with other biological elements in living tissue, as well as from gamma rays leaked from the reactor core. At Dalat Research Reactor, Vietnam, the neutron and gamma dose rate distribution inside a water phantom were measured by using activation method and Thermoluminescent Dosimeter (TLD) detector, respectively. The results showed that effective thermal neutron dose rate along the center line of the water phantom had a maximum value of 479 mSv h(-1) at 1 cm in phantom and then decreases rapidly to 4.87 mSv h(-1) at 10 cm. The gamma dose rate along the center line of the water phantom also reach its maximum of 4.31 mSv h(-1) at 1 cm depth and decreases to 1.16 mSv h(-1) at 10 cm position. The maximum biological tumor dose rate was 1.74 Gy-eqh(-1), not high enough to satisfy the treatment requirement of brain tumors. However, the results of this work are important in supporting of BNCT study in the upcoming stages at Dalat Research Reactor. -
dc.identifier.bibliographicCitation SAINS MALAYSIANA, v.48, no.1, pp.191 - 197 -
dc.identifier.doi 10.17576/jsm-2019-4801-22 -
dc.identifier.issn 0126-6039 -
dc.identifier.scopusid 2-s2.0-85062277948 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/26341 -
dc.identifier.url http://www.ukm.my/jsm/pdf_files/SM-PDF-48-1-2019/22%20Trinh%20Thi%20Tu%20Anh.pdf -
dc.identifier.wosid 000459984200022 -
dc.language 영어 -
dc.publisher UNIV KEBANGSAAN MALAYSIA -
dc.title Measurement of Neutron Flux and Gamma Dose Rate Distribution Inside a Water Phantom, for Boron Neutron Capture Therapy Study at Dalat Research Reactor -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Multidisciplinary Sciences -
dc.relation.journalResearchArea Science & Technology - Other Topics -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor water phantom -
dc.subject.keywordAuthor BNCT -
dc.subject.keywordAuthor dose rate -
dc.subject.keywordAuthor TLD detector -
dc.subject.keywordAuthor thermal neutron flux -
dc.subject.keywordPlus IRRADIATION FIELD -
dc.subject.keywordPlus BNCT -
dc.subject.keywordPlus DESIGN -
dc.subject.keywordPlus BEAM -
dc.subject.keywordPlus DOSIMETRY -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.