File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 5387 -
dc.citation.number 22 -
dc.citation.startPage 5380 -
dc.citation.title ANALYST -
dc.citation.volume 143 -
dc.contributor.author Ahn, DaeHhn -
dc.contributor.author Lee, JiYeong -
dc.contributor.author Moon, SangJun -
dc.contributor.author Park, Taejoon -
dc.date.accessioned 2023-12-21T20:06:41Z -
dc.date.available 2023-12-21T20:06:41Z -
dc.date.created 2018-12-11 -
dc.date.issued 2018-11 -
dc.description.abstract In point-of-care testing, in-line holographic microscopes paved the way for realizing portable cell counting systems at marginal cost. To maximize their accuracy, it is critically important to reliably count the number of cells even in noisy blood images overcoming various problems due to out-of-focus blurry cells and background brightness variations. However, previous studies could detect cells only on clean images while they failed to accurately distinguish blurry cells from background noises. To address this problem, we present a human-level blood cell counting system by synergistically integrating the methods of normalized cross-correlation (NCC) and a convolutional neural network (CNN). Our comprehensive performance evaluation demonstrates that the proposed system achieves the highest level of accuracy (96.7-98.4%) for any kinds of blood cells on a lens-free shadow image while others suffer from significant accuracy degradations (12.9-38.9%) when detecting blurry cells. Moreover, it outperforms others by up to 36.8% in accurately analyzing noisy blood images and is 24.0-40.8× faster, thus maximizing both accuracy and computational efficiency. -
dc.identifier.bibliographicCitation ANALYST, v.143, no.22, pp.5380 - 5387 -
dc.identifier.doi 10.1039/c8an01056k -
dc.identifier.issn 0003-2654 -
dc.identifier.scopusid 2-s2.0-85056209085 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/25443 -
dc.identifier.url https://pubs.rsc.org/en/Content/ArticleLanding/2018/AN/C8AN01056K#!divAbstract -
dc.identifier.wosid 000456684800007 -
dc.language 영어 -
dc.publisher ROYAL SOC CHEMISTRY -
dc.title Human-level blood cell counting on lens-free shadow images exploiting deep neural networks -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Chemistry, Analytical -
dc.relation.journalResearchArea Chemistry -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.