File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

양준모

Yang, Joon Mo
Medical Device and System Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 101 -
dc.citation.number 1 -
dc.citation.startPage 96 -
dc.citation.title KEY ENGINEERING MATERIALS -
dc.citation.volume 277-279 -
dc.contributor.author Jung, Hyun Hee -
dc.contributor.author Yang, Joon Mo -
dc.contributor.author Woo, Won Myung -
dc.contributor.author Yi, Seung Ho -
dc.contributor.author Yang, JS -
dc.contributor.author Soh, Kwang Sup -
dc.date.accessioned 2023-12-22T10:39:29Z -
dc.date.available 2023-12-22T10:39:29Z -
dc.date.created 2018-05-08 -
dc.date.issued 2005 -
dc.description.abstract The signal characteristics of the biophotons from human hands were studied using correlation and δ-value analyses. Three healthy individuals without any history of disease participated in the measurements, six times every Friday for 52 weeks, while staying in a room with dim lighting to eliminate any delayed luminescence caused by the sun or room lights. Two head-on type photomultiplier tubes inside a dark room were used to simultaneously measure the biophoton emissions from the palm and dorsum of the left and right hand with a 100ms gate time. In view of the signal process, a cross-correlation of the long-term data, i.e. the weekly measurements, revealed a strong correlation between the signals from the left and right hand, yet only a very weak correlation between the palm and dorsum. The non-classical light property of the biophotons, that has a quantum coherence nature, was compared with that of the dark counts of the PMTs using a δ- value analysis. The average δ-value for the biophotons was 0.08±0.07. As such, it was found that the palm emissions were very coherent, while the dorsum emissions showed an occasional lack of coherence. -
dc.identifier.bibliographicCitation KEY ENGINEERING MATERIALS, v.277-279, no.1, pp.96 - 101 -
dc.identifier.issn 1013-9826 -
dc.identifier.scopusid 2-s2.0-33646397591 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/24076 -
dc.identifier.url https://www.scientific.net/KEM.277-279.96 -
dc.language 영어 -
dc.publisher Trans Tech Publications Ltd. -
dc.title Signal characteristics of biophoton emission from human hands -
dc.type Article -
dc.description.journalRegisteredClass scopus -

qrcode