There are no files associated with this item.
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.citation.endPage | 23953 | - |
dc.citation.number | 21 | - |
dc.citation.startPage | 23944 | - |
dc.citation.title | OPTICS EXPRESS | - |
dc.citation.volume | 20 | - |
dc.contributor.author | Yang, Joon-Mo | - |
dc.contributor.author | Chen, Ruimin | - |
dc.contributor.author | Favazza, Christopher | - |
dc.contributor.author | Yao, Junjie | - |
dc.contributor.author | Li, Chiye | - |
dc.contributor.author | Hu, Zhilin | - |
dc.contributor.author | Zhou, Qifa | - |
dc.contributor.author | Shung, K. Kirk | - |
dc.contributor.author | Wang, Lihong V. | - |
dc.date.accessioned | 2023-12-22T04:39:08Z | - |
dc.date.available | 2023-12-22T04:39:08Z | - |
dc.date.created | 2018-05-04 | - |
dc.date.issued | 2012-10 | - |
dc.description.abstract | We have created a 2.5-mm outer diameter integrated photoacoustic and ultrasonic mini-probe which can be inserted into a standard video endoscope's instrument channel. A small-diameter focused ultrasonic transducer made of PMN-PT provides adequate signal sensitivity, and enables miniaturization of the probe. Additionally, this new endoscopic probe utilizes the same scanning mirror and micromotor-based built-in actuator described in our previous reports; however, the length of the rigid distal section of the new probe has been further reduced to similar to 35 mm. This paper describes the technical details of the mini-probe and presents experimental results that both quantify the imaging performance and demonstrate its in vivo imaging capability, which suggests that it could work as a mini-probe for certain clinical applications. | - |
dc.identifier.bibliographicCitation | OPTICS EXPRESS, v.20, no.21, pp.23944 - 23953 | - |
dc.identifier.doi | 10.1364/OE.20.023944 | - |
dc.identifier.issn | 1094-4087 | - |
dc.identifier.scopusid | 2-s2.0-84867301325 | - |
dc.identifier.uri | https://scholarworks.unist.ac.kr/handle/201301/24062 | - |
dc.identifier.url | https://www.osapublishing.org/oe/abstract.cfm?uri=oe-20-21-23944 | - |
dc.identifier.wosid | 000309955100100 | - |
dc.language | 영어 | - |
dc.publisher | OPTICAL SOC AMER | - |
dc.title | A 2.5-mm diameter probe for photoacoustic and ultrasonic endoscopy | - |
dc.type | Article | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordPlus | OPTICAL COHERENCE TOMOGRAPHY | - |
dc.subject.keywordPlus | IN-VIVO | - |
dc.subject.keywordPlus | BIOLOGICAL TISSUE | - |
dc.subject.keywordPlus | MICROSCOPY | - |
dc.subject.keywordPlus | BIOPSY | - |
dc.subject.keywordPlus | CANCER | - |
dc.subject.keywordPlus | NEEDLE | - |
dc.subject.keywordPlus | ORGANS | - |
dc.subject.keywordPlus | BLOOD | - |
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Tel : 052-217-1404 / Email : scholarworks@unist.ac.kr
Copyright (c) 2023 by UNIST LIBRARY. All rights reserved.
ScholarWorks@UNIST was established as an OAK Project for the National Library of Korea.