There are no files associated with this item.
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.citation.number | 6 | - |
dc.citation.startPage | 066001 | - |
dc.citation.title | JOURNAL OF BIOMEDICAL OPTICS | - |
dc.citation.volume | 19 | - |
dc.contributor.author | Yang, Joon-Mo | - |
dc.contributor.author | Li, Chiye | - |
dc.contributor.author | Chen, Ruimin | - |
dc.contributor.author | Zhou, Qifa | - |
dc.contributor.author | Shung, K. Kirk | - |
dc.contributor.author | Wang, Lihong V. | - |
dc.date.accessioned | 2023-12-22T02:37:48Z | - |
dc.date.available | 2023-12-22T02:37:48Z | - |
dc.date.created | 2018-05-04 | - |
dc.date.issued | 2014-06 | - |
dc.description.abstract | We report a flexible shaft-based mechanical scanning photoacoustic endoscopy (PAE) system that can be potentially used for imaging the human gastrointestinal tract via the instrument channel of a clinical video endoscope. The development of such a catheter endoscope has been an important challenge to realize the technique's benefits in clinical settings. We successfully implemented a prototype PAE system that has a 3.2-mm diameter and 2.5-m long catheter section. As the instrument's flexible shaft and scanning tip are fully encapsulated in a plastic catheter, it easily fits within the 3.7-mm diameter instrument channel of a clinical video endoscope. Here, we demonstrate the intra-instrument channel workability and in vivo animal imaging capability of the PAE system. | - |
dc.identifier.bibliographicCitation | JOURNAL OF BIOMEDICAL OPTICS, v.19, no.6, pp.066001 | - |
dc.identifier.doi | 10.1117/1.JBO.19.6.066001 | - |
dc.identifier.issn | 1083-3668 | - |
dc.identifier.scopusid | 2-s2.0-84902094411 | - |
dc.identifier.uri | https://scholarworks.unist.ac.kr/handle/201301/24060 | - |
dc.identifier.url | https://www.spiedigitallibrary.org/journals/Journal-of-Biomedical-Optics/volume-19/issue-06/066001/Catheter-based-photoacoustic-endoscope/10.1117/1.JBO.19.6.066001.full?SSO=1 | - |
dc.identifier.wosid | 000340432900008 | - |
dc.language | 영어 | - |
dc.publisher | SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS | - |
dc.title | Catheter-based photoacoustic endoscope | - |
dc.type | Article | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Tel : 052-217-1404 / Email : scholarworks@unist.ac.kr
Copyright (c) 2023 by UNIST LIBRARY. All rights reserved.
ScholarWorks@UNIST was established as an OAK Project for the National Library of Korea.