File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

권영남

Kwon, Young-Nam
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 158 -
dc.citation.startPage 147 -
dc.citation.title DESALINATION -
dc.citation.volume 430 -
dc.contributor.author Park, Hyung-Gyu -
dc.contributor.author Kwon, Young-Nam -
dc.date.accessioned 2023-12-21T21:08:03Z -
dc.date.available 2023-12-21T21:08:03Z -
dc.date.created 2018-01-29 -
dc.date.issued 2018-03 -
dc.description.abstract The dominant factors on determination of permeate pH in the reverse osmosis (RO) membrane process have been systematically investigated to further our understanding of the separation mechanisms of the RO process. The surface of a commercial RO membrane was modified to neutralize the surface charge, and the effect of surface properties including charge on both the pH shift and individual ion removal rate during the filtration was studied. Then, the pH shift of aqueous solution during the filtration was evaluated throughout a broad range of feed pH, from pH 3 to 12, with or without carbonate species in the feed water. The permeate pH values were predicted on the basis of the ion rejection of the RO membrane, charge balance of the aqueous solution, and dynamic equilibrium in the dissociation of water. The predicted pH values were then compared with both experimental data acquired in flat sheet filtration tests in a laboratory and pH data obtained from a commercially operating RO plant. The results support the hypothesis that the ion rejection of the RO membrane is one of main factor to determine the degree of shift in pH and the critical pH is influenced by the feed water characteristics. -
dc.identifier.bibliographicCitation DESALINATION, v.430, pp.147 - 158 -
dc.identifier.doi 10.1016/j.desal.2017.12.060 -
dc.identifier.issn 0011-9164 -
dc.identifier.scopusid 2-s2.0-85039986869 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/23266 -
dc.identifier.url https://www.sciencedirect.com/science/article/pii/S0011916417316363?via%3Dihub -
dc.identifier.wosid 000424173900015 -
dc.language 영어 -
dc.publisher ELSEVIER SCIENCE BV -
dc.title Investigation on the factors determining permeate pH in reverse osmosis membrane processes -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Engineering, Chemical; Water Resources -
dc.relation.journalResearchArea Engineering; Water Resources -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Charge balance -
dc.subject.keywordAuthor Electroneutrality -
dc.subject.keywordAuthor Feed pH -
dc.subject.keywordAuthor Permeate pH -
dc.subject.keywordAuthor Polyamide RO -
dc.subject.keywordPlus POLYAMIDE NANOFILTRATION MEMBRANES -
dc.subject.keywordPlus BORON REMOVAL -
dc.subject.keywordPlus COMPOSITE MEMBRANES -
dc.subject.keywordPlus NF MEMBRANES -
dc.subject.keywordPlus HYPOCHLORITE DEGRADATION -
dc.subject.keywordPlus SURFACE MODIFICATION -
dc.subject.keywordPlus SOLUTION CHEMISTRY -
dc.subject.keywordPlus SWRO MEMBRANES -
dc.subject.keywordPlus ION REJECTION -
dc.subject.keywordPlus PERFORMANCE -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.