File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

방인철

Bang, In Cheol
Nuclear Thermal Hydraulics and Reactor Safety Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 483 -
dc.citation.startPage 472 -
dc.citation.title INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER -
dc.citation.volume 119 -
dc.contributor.author Kim, Kyung Mo -
dc.contributor.author Bang, In Cheol -
dc.date.accessioned 2023-12-21T21:06:36Z -
dc.date.available 2023-12-21T21:06:36Z -
dc.date.created 2017-12-03 -
dc.date.issued 2018-04 -
dc.description.abstract In this study, a new type of thermosyphon, the hybrid heat pipe-control rod, was suggested as a passive decay heat removal device in nuclear facilities. A self-pressurization strategy, which is a passive pressure control mechanism, was introduced to achieve high operating pressure in the hybrid heat pipe, because most nuclear facilities are under high-pressure and high-temperature conditions. In the introduced pressurization strategy, a non-condensable gas was charged, and the steam generated, by the phase change of the working fluid during operation, was used as a pressurization source. The feasibility of the pressure control mechanism was experimentally studied using test sections containing nitrogen gas and water as non-condensable gas and working fluid, respectively. Consequently, it was confirmed that the internal pressure of the hybrid heat pipe was increased up to 19.0 bar through the self-pressurization mechanism under the conditions in which the experiments were conducted. Furthermore, the dependencies of the pressure behavior, heat transfer coefficients at the evaporator and adiabatic sections, and flooding based maximum heat transfer rate on the working fluid fill ratio, initial pressure, and heat load were discussed. The evaporation heat transfer coefficient was independent of the fill ratio and initial pressure, while the condensation heat transfer was inversely proportional to the amount of non-condensable gas charged inside the test section. The maximum heat transfer rate increased as the operating pressure increased, owing to the reduction of entrainment rate. Based on the experimental results, new models on condensation heat transfer and flooding limit were proposed, considering the effects of the non condensable gas and different cross-sectional areas along the evaporator and adiabatic sections of the hybrid heat pipe. -
dc.identifier.bibliographicCitation INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, v.119, pp.472 - 483 -
dc.identifier.doi 10.1016/j.ijheatmasstransfer.2017.11.138 -
dc.identifier.issn 0017-9310 -
dc.identifier.scopusid 2-s2.0-85036464157 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/23026 -
dc.identifier.url http://www.sciencedirect.com/science/article/pii/S0017931017333409 -
dc.identifier.wosid 000423893700042 -
dc.language 영어 -
dc.publisher PERGAMON-ELSEVIER SCIENCE LTD -
dc.title Thermal-hydraulic phenomena inside hybrid heat pipe-control rod for passive heat removal -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Thermodynamics; Engineering, Mechanical; Mechanics -
dc.relation.journalResearchArea Thermodynamics; Engineering; Mechanics -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Hybrid heat pipe -
dc.subject.keywordAuthor Thermosyphon -
dc.subject.keywordAuthor Passive safety -
dc.subject.keywordAuthor Nuclear safety -
dc.subject.keywordAuthor Heat transfer -
dc.subject.keywordAuthor Flooding -
dc.subject.keywordPlus CONDENSATION -
dc.subject.keywordPlus LIMIT -
dc.subject.keywordPlus PERFORMANCE -
dc.subject.keywordPlus FLUX -
dc.subject.keywordPlus CHF -

qrcode