File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

신명수

Shin, Myoungsu
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 1169 -
dc.citation.number 22 -
dc.citation.startPage 1157 -
dc.citation.title MAGAZINE OF CONCRETE RESEARCH -
dc.citation.volume 69 -
dc.contributor.author Mai-Quang, Khai -
dc.contributor.author Han, Sang Whan -
dc.contributor.author Shin, Myoungsu -
dc.contributor.author Lee, Kihak -
dc.date.accessioned 2023-12-21T21:38:53Z -
dc.date.available 2023-12-21T21:38:53Z -
dc.date.created 2017-10-16 -
dc.date.issued 2017-11 -
dc.description.abstract The current design method in the ACI building code 318M-14 for reinforced-concrete coupling beams requires complex details, which leads to reinforcement congestion and difficulty in construction. As an original solution for this issue, the use of steel fibres to reduce the amount of transverse and bundled diagonal reinforcement in coupling beams is investigated in this study. In order to estimate the effect of the expected design method, four coupling beam specimens with 2/3 scale subjected to cyclic lateral loads were tested. All specimens were made of steel-fibre-reinforced concrete. One specimen complied with ACI code-specified reinforcement details (for all diagonal, transverse and horizontal bars) and three specimens used bundled diagonal reinforcement with variation in the spacing of stirrups. The global behaviours of the tested coupling beams are discussed, especially focusing on the strength, ductility and energy dissipation capacity as displacement demand increases. The test results illustrate that the lateral force-resisting performance of coupling beams was effectively improved by using steel fibres and bundled diagonal reinforcement, even with a reduced amount of stirrups, compared to that designed following ACI code-specified reinforcement details. -
dc.identifier.bibliographicCitation MAGAZINE OF CONCRETE RESEARCH, v.69, no.22, pp.1157 - 1169 -
dc.identifier.doi 10.1680/jmacr.16.00530 -
dc.identifier.issn 0024-9831 -
dc.identifier.scopusid 2-s2.0-85031317490 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/22797 -
dc.identifier.url https://doi.org/10.1680/jmacr.16.00530 -
dc.identifier.wosid 000412979900003 -
dc.language 영어 -
dc.publisher ICE PUBL -
dc.title Reduction of reinforcement congestion in slender coupling beam using bundled diagonal bars -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Construction & Building Technology; Materials Science, Multidisciplinary -
dc.relation.journalResearchArea Construction & Building Technology; Materials Science -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor fibre-reinforced concrete -
dc.subject.keywordAuthor structural analysis -
dc.subject.keywordAuthor testing -
dc.subject.keywordAuthor structural elements -
dc.subject.keywordPlus BEHAVIOR -
dc.subject.keywordPlus PERFORMANCE -
dc.subject.keywordPlus COMPOSITES -
dc.subject.keywordPlus DUCTILITY -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.