File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

김용환

Kim, Yong Hwan
Enzyme and Protein Engineering Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 104 -
dc.citation.number 1 -
dc.citation.startPage 100 -
dc.citation.title BULLETIN OF THE KOREAN CHEMICAL SOCIETY -
dc.citation.volume 33 -
dc.contributor.author Park, Buem Jin -
dc.contributor.author Sa, Young Seung -
dc.contributor.author Kim, Yong Hwan -
dc.contributor.author Kim, Younghun -
dc.date.accessioned 2023-12-22T05:36:38Z -
dc.date.available 2023-12-22T05:36:38Z -
dc.date.created 2016-09-06 -
dc.date.issued 2012-01 -
dc.description.abstract Thrombin is a serine protease that catalyzes the conversion of soluble fibrinogen to insoluble fibrin, and thus induces physiological and pathological blood coagulation. Therefore, it is important to detect thrombin in blood serum for purposes of diagnosis. To achieve this goal, it has been suggested that a 15-mer aptamer strongly binds with thrombin to form a G-quartet structure of the aptamer. Generally, 5'-end thiol-functionalized aptamer has been used as an anti-thrombin binder. Herein, we evaluate the possibility of utilizing a 3'-SH aptasensor for thrombin detection using SPR spectroscopy, and compare the enhancement of the electrochemical signal of the thrombin-aptamer bound on a porous gold substrate. Although the two aptamers have similar configurations, in SPR analysis, the 3'-SH aptamer was a effective aptasensor as well as 5'-SH aptamer. Results from electrochemical analysis showed that the porous gold substrate acted as a good substrate for an aptasensor and demonstrated 5-fold enhancement of current change, as compared to gold thin film -
dc.identifier.bibliographicCitation BULLETIN OF THE KOREAN CHEMICAL SOCIETY, v.33, no.1, pp.100 - 104 -
dc.identifier.doi 10.5012/bkcs.2012.33.1.100 -
dc.identifier.issn 1229-5949 -
dc.identifier.scopusid 2-s2.0-84862908696 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/20366 -
dc.identifier.url http://www.koreascience.or.kr/article/ArticleFullRecord.jsp?cn=JCGMCS_2012_v33n1_100&ordernum=17 -
dc.identifier.wosid 000300473700017 -
dc.language 영어 -
dc.publisher KOREAN CHEMICAL SOC -
dc.title Spectroscopic and Electrochemical Detection of Thrombin/5 '-SH or 3 '-SH Aptamer Immobilized on (porous) Gold Substrates -
dc.type Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Aptamer -
dc.subject.keywordAuthor Thrombin -
dc.subject.keywordAuthor SPR sensor -
dc.subject.keywordAuthor CV -
dc.subject.keywordAuthor porous gold -
dc.subject.keywordPlus MOLECULAR RECOGNITION ELEMENTS -
dc.subject.keywordPlus NANOPARTICLES -
dc.subject.keywordPlus INHIBITORS -
dc.subject.keywordPlus BIOSENSOR -
dc.subject.keywordPlus ASSAY -
dc.subject.keywordPlus BIND -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.