File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

신명수

Shin, Myoungsu
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 62 -
dc.citation.number 2 -
dc.citation.startPage 55 -
dc.citation.title 한국지진공학회논문집 -
dc.citation.volume 19 -
dc.contributor.author Han, Sang Whan -
dc.contributor.author Yu, Kyung Hwan -
dc.contributor.author Kang, Dong Hun -
dc.contributor.author Lee, Kihak -
dc.contributor.author Shin, Myoungsu -
dc.date.accessioned 2023-12-22T01:37:08Z -
dc.date.available 2023-12-22T01:37:08Z -
dc.date.created 2015-12-29 -
dc.date.issued 2015-03 -
dc.description.abstract Shear wall systems behave as individual wall because of openings like window and elevator cage. When coupling beams are installed in shear walls, they will have high strength and stiffness so that be less damaged by lateral loads like earthquake. However, coupling beam is difficult construction method. And arranging reinforcement of slender coupling beams are especially hard. It is because the details of coupling beam provided by ACI 318 are complex. In this paper, experiments were conducted using coupling beams with 3.5 aspect ratio to improve the details of slender coupling beams provided by ACI 318. Two specimens were proposed for this study. One specimen applied with bundled diagonally reinforcement only. Another specimen applied both bundled diagonally reinforcement and High-Performance Fiber Reinforced Cementitious Composite (HPFRCC) so that coupling beams have half of transverse reinforcement. All specimen were compared with a coupling beam designed according to ACI 318 and were evaluated with hysteretic behaviors. Test results showed that the performance of two specimen suggested in this study were similar to that of coupling beam designed according to current criteria. And it was considered that simplification of the details of reinforcement would be available if transverse reinforcement was reduced by using bundled diagonally reinforcement and HPFRCC. -
dc.identifier.bibliographicCitation 한국지진공학회논문집, v.19, no.2, pp.55 - 62 -
dc.identifier.issn 1226-525X -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/18131 -
dc.identifier.url http://scholar.ndsl.kr/schDetail.do?cn=JAKO201509057414283 -
dc.language 한국어 -
dc.publisher 한국지진공학회 -
dc.title.alternative Cyclic Behavior of Precast Slender Coupling Beams with Bundled Diagonally Reinforcement and High-Performance Fiber Reinforced Cementitious Composite(HPFRCC) -
dc.title 묶음 대각철근과 고성능 섬유보강 시멘트 복합체를 적용한 세장한 프리캐스트 연결보의 이력거동 평가 -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.identifier.kciid ART001966196 -
dc.description.journalRegisteredClass kci -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.