There are no files associated with this item.
Cited time in
Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.citation.endPage | 101 | - |
| dc.citation.startPage | 89 | - |
| dc.citation.title | CONSTRUCTION AND BUILDING MATERIALS | - |
| dc.citation.volume | 106 | - |
| dc.contributor.author | Quang, Khai Mai | - |
| dc.contributor.author | Phuoc, V.B. Phuoc | - |
| dc.contributor.author | Han, Sang Whan | - |
| dc.contributor.author | Shin, Myoungsu | - |
| dc.contributor.author | Lee, Kihak | - |
| dc.date.accessioned | 2023-12-22T00:08:24Z | - |
| dc.date.available | 2023-12-22T00:08:24Z | - |
| dc.date.created | 2016-01-05 | - |
| dc.date.issued | 2016-03 | - |
| dc.description.abstract | Current design in the ACI building code for reinforced concrete columns under seismic load combinations requires reinforced detailing which causes reinforcement congestion and construction difficulties. As an alternative solution, the use of high-performance fiber-reinforced cement composites (HPFRCC) with an economical type of Poly Vinyl Alcohol (PVA) fibers in column elements was investigated in this paper. Six column specimens with 2/3 scale including three standard reinforced columns and three columns using PVA fibers were tested. In the research work herein presented, biaxial cyclic lateral loads were applied to specimens subjected to either 10% or 30% constant axial loads. The experimental results are presented and the global behaviors of the tested columns are discussed, particularly focusing on stiffness and strength degradations due to increasing cyclic demand. Test results indicated superior damage tolerance and stable inelastic load-displacement responses up to 5% or 9% drift for the HPFRCC columns, even though they suffered severe shear cracks. Specimens without PVA all showed very limited ductility and low strengths. © 2015 Elsevier Ltd. All rights reserved | - |
| dc.identifier.bibliographicCitation | CONSTRUCTION AND BUILDING MATERIALS, v.106, pp.89 - 101 | - |
| dc.identifier.doi | 10.1016/j.conbuildmat.2015.12.087 | - |
| dc.identifier.issn | 0950-0618 | - |
| dc.identifier.scopusid | 2-s2.0-84950974852 | - |
| dc.identifier.uri | https://scholarworks.unist.ac.kr/handle/201301/18027 | - |
| dc.identifier.url | http://www.sciencedirect.com/science/article/pii/S0950061815307595 | - |
| dc.identifier.wosid | 000370103400010 | - |
| dc.language | 영어 | - |
| dc.publisher | ELSEVIER SCI LTD | - |
| dc.title | Behavior of high-performance fiber-reinforced cement composite columns subjected to horizontal biaxial and axial loads | - |
| dc.type | Article | - |
| dc.description.isOpenAccess | FALSE | - |
| dc.relation.journalWebOfScienceCategory | Construction & Building Technology; Engineering, Civil; Materials Science, Multidisciplinary | - |
| dc.relation.journalResearchArea | Construction & Building Technology; Engineering; Materials Science | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.subject.keywordAuthor | Biaxial testing | - |
| dc.subject.keywordAuthor | Energy dissipation | - |
| dc.subject.keywordAuthor | HPFRCC | - |
| dc.subject.keywordAuthor | Hysteresis loop | - |
| dc.subject.keywordAuthor | PVA fibers | - |