There are no files associated with this item.
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.citation.endPage | S1471 | - |
dc.citation.startPage | S1465 | - |
dc.citation.title | BIO-MEDICAL MATERIALS AND ENGINEERING | - |
dc.citation.volume | 26 | - |
dc.contributor.author | Shirazi, Muhammad Faizan | - |
dc.contributor.author | Cho, Nam Hyun | - |
dc.contributor.author | Jung, Woonggyu | - |
dc.contributor.author | Kim, Jeehyun | - |
dc.date.accessioned | 2023-12-22T00:49:59Z | - |
dc.date.available | 2023-12-22T00:49:59Z | - |
dc.date.created | 2015-10-21 | - |
dc.date.issued | 2015-08 | - |
dc.description.abstract | Adaptive optics plays an important role in the correction of high-order aberrations to enhance lateral resolution. An OCT system coupled with a programmable phase modulator is designed to verify lateral resolution improvement. The Hamamatsu high-resolution, non-pixelized, optically addressed light modulator (PAL-SLM) PPM X7550 series is used to correct aberrations, utilizing a simple method based on phase information from OCT images. The advantages of this method are its high simplicity and low cost. A raster scanning technique is adopted to scan samples covered with scattering suspension. Metal lines covered with scattering suspension are imaged, and a respective correction is applied to remove the aberration. Results demonstrate an improvement in lateral resolution on metal grid samples | - |
dc.identifier.bibliographicCitation | BIO-MEDICAL MATERIALS AND ENGINEERING, v.26, pp.S1465 - S1471 | - |
dc.identifier.doi | 10.3233/BME-151445 | - |
dc.identifier.issn | 0959-2989 | - |
dc.identifier.scopusid | 2-s2.0-84977467092 | - |
dc.identifier.uri | https://scholarworks.unist.ac.kr/handle/201301/17483 | - |
dc.identifier.url | http://content.iospress.com/articles/bio-medical-materials-and-engineering/bme1445 | - |
dc.identifier.wosid | 000361671800163 | - |
dc.language | 영어 | - |
dc.publisher | IOS PRESS | - |
dc.title | Lateral resolution enhancement using programmable phase modulator in optical coherence tomography | - |
dc.type | Article | - |
dc.description.isOpenAccess | FALSE | - |
dc.relation.journalWebOfScienceCategory | Engineering, Biomedical; Materials Science, Biomaterials | - |
dc.relation.journalResearchArea | Engineering; Materials Science | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordAuthor | OCT | - |
dc.subject.keywordAuthor | lateral resolution | - |
dc.subject.keywordAuthor | aberration correction | - |
dc.subject.keywordAuthor | adaptive optics | - |
dc.subject.keywordAuthor | PAL-SLM | - |
dc.subject.keywordPlus | LIVING RETINA | - |
dc.subject.keywordPlus | IMAGE | - |
dc.subject.keywordPlus | QUALITY | - |