File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

김예린

Kim, Katherine A.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 1130 -
dc.citation.number 2 -
dc.citation.startPage 1121 -
dc.citation.title IEEE TRANSACTIONS ON POWER ELECTRONICS -
dc.citation.volume 31 -
dc.contributor.author Kim, Katherine A. -
dc.contributor.author Seo, Gab-Su -
dc.contributor.author Cho, Bo-Hyung -
dc.contributor.author Krein, Philip T. -
dc.date.accessioned 2023-12-22T00:11:17Z -
dc.date.available 2023-12-22T00:11:17Z -
dc.date.created 2015-08-02 -
dc.date.issued 2016-02 -
dc.description.abstract Hot spotting is a problem in photovoltaic (PV) systems that reduces panel power performance and accelerates cell degradation. In present day systems, bypass diodes are used to mitigate hot spotting, but it does not prevent hot spotting or the damage it causes. This paper presents an active hot spot detection method to detect hot spotting within a series of PV cells, using ac parameter characterization. A PV cell is comprised of series and parallel resistances and parallel capacitance, which are affected by voltage bias, illumination, and temperature. Experimental results have shown that when a PV string is under a maximum power point tracking control, hot spotting in a single cell results in a capacitance increase and dc impedance increase. The capacitance change is detectable by measuring the ac impedance magnitude in the 10-70 kHz frequency range. An impedance value change due to hot spotting can be detected by monitoring one high-frequency measurement in the capacitive region and one low-frequency measurement in the dc impedance region. Alternatively, the dc impedance can also be calculated using dc operating point measurements. The proposed hot spot detection method can be integrated into a dc-dc power converter that operates at the panel or subpanel level. -
dc.identifier.bibliographicCitation IEEE TRANSACTIONS ON POWER ELECTRONICS, v.31, no.2, pp.1121 - 1130 -
dc.identifier.doi 10.1109/TPEL.2015.2417548 -
dc.identifier.issn 0885-8993 -
dc.identifier.scopusid 2-s2.0-84944096315 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/13370 -
dc.identifier.url http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7072567 -
dc.identifier.wosid 000362364000018 -
dc.language 영어 -
dc.publisher IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC -
dc.title Photovoltaic Hot Spot Detection for Solar Panel Substrings Using AC Parameter Characterization -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Engineering, Electrical & Electronic -
dc.relation.journalResearchArea Engineering -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Fault detection -
dc.subject.keywordAuthor impedance measurement -
dc.subject.keywordAuthor photovoltaic (PV) hot spot -
dc.subject.keywordAuthor partial shading -
dc.subject.keywordAuthor PV systems -
dc.subject.keywordPlus POWER POINT TRACKING -
dc.subject.keywordPlus MISMATCH -
dc.subject.keywordPlus BSFR -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.