File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

김성필

Kim, Sung-Phil
Brain-Computer Interface Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 72 -
dc.citation.startPage 68 -
dc.citation.title NEUROSCIENCE LETTERS -
dc.citation.volume 602 -
dc.contributor.author Kim, Hyung-Sik -
dc.contributor.author Kim, Ji Sun -
dc.contributor.author Jung, Gu-In -
dc.contributor.author Jun, Jae-Hoon -
dc.contributor.author Park, Jong-Rak -
dc.contributor.author Kim, Sung-Phil -
dc.contributor.author Choi, Seungmoon -
dc.contributor.author Park, Sung-Jun -
dc.contributor.author Choi, Mi-Hyun -
dc.contributor.author Chung, Soon-Cheol -
dc.date.accessioned 2023-12-22T01:06:37Z -
dc.date.available 2023-12-22T01:06:37Z -
dc.date.created 2015-07-29 -
dc.date.issued 2015-08 -
dc.description.abstract In this study, we examined the possibility and perceptual response characteristics of tactile sense induced by laser stimulation to the finger with different laser energy densities through human response experiments. 15 healthy adult males and 4 healthy adult females with an age of 22.6 ± 2.2 years were tested. A frequency-doubled Q-switched laser was used with a wavelength of 532 nm and a 5 ns pulse width. The experimental trial spanned a total of 30 s and included a rest phase (19 s), a stimulation phase (7 s), and a response phase (4 s). During the rest phase, subjects kept their fingers comfortable. During the stimulation phase, one of three types of laser energy density (13.5, 16.6, 19.8 mJ/cm2) or a sham stimulation was used to irradiate the distal phalanx on the right index finger. During the response phase, the cognitive response to the laser stimulation was recorded by a PC by pressing the response button. The confusion matrix was configured to evaluate the possibility that the tactile sense was caused by the laser. In addition, changes in the response characteristics were observed according to three types of laser energy densities. From the analysis of the confusion matrix, the accuracy and sensitivity were not high. In contrast, precision and specificity were found to be high. Furthermore, there was a strong positive correlation between the laser irradiation and tactile perception, indicating that tactile sense can be induced using a laser in a mid-air manner. In addition, it was found that as the laser energy density increased, the tactile perception possibility also increased. -
dc.identifier.bibliographicCitation NEUROSCIENCE LETTERS, v.602, pp.68 - 72 -
dc.identifier.doi 10.1016/j.neulet.2015.06.053 -
dc.identifier.issn 0304-3940 -
dc.identifier.scopusid 2-s2.0-84938059472 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/13046 -
dc.identifier.url http://www.sciencedirect.com/science/article/pii/S0304394015300148 -
dc.identifier.wosid 000360596400013 -
dc.language 영어 -
dc.publisher ELSEVIER IRELAND LTD -
dc.title Evaluation of the possibility and response characteristics of laser-induced tactile sensation -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Neurosciences -
dc.relation.journalResearchArea Neurosciences & Neurology -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Laser energy density -
dc.subject.keywordAuthor Possibility evaluation -
dc.subject.keywordAuthor Pulse laser -
dc.subject.keywordAuthor Tactile sense -
dc.subject.keywordPlus STIMULATOR -
dc.subject.keywordPlus PRESSURE -
dc.subject.keywordPlus DEVICE -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.