File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

김성진

Kim, Seong-Jin
Bio-inspired Advanced Sensors Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 381 -
dc.citation.startPage 375 -
dc.citation.title SENSORS AND ACTUATORS B-CHEMICAL -
dc.citation.volume 213 -
dc.contributor.author Chen, Yu -
dc.contributor.author Kim, Seong-Jin -
dc.contributor.author Guo, Jinhong -
dc.contributor.author Kang, Yuejun -
dc.contributor.author Kausalyac, Jaya P. -
dc.contributor.author Ongc, Alicia Ghia Min -
dc.contributor.author Hunzikerc, Walter -
dc.contributor.author Chung, Jaehoon -
dc.date.accessioned 2023-12-22T01:08:06Z -
dc.date.available 2023-12-22T01:08:06Z -
dc.date.created 2015-07-16 -
dc.date.issued 2015-07 -
dc.description.abstract A high-throughput Coulter counter for point-of-care (POC) applications has been developed, which measures the concentration and size distribution of cells in suspension at a single cell resolution. Vertical channels (silicon-based through-holes), instead of conventional planar ones, were employed to achieve a higher density of sensing channels for a high-throughput operation. The crosstalk from the multiple sensing channels was minimized by potentiometric measurement based on a three-electrode configuration, decoupling the neighboring channels electrically. The through-hole array and potentiometric sensing increased throughput up to 8000 cells/s in the prototype (designed with four channels). To secure the sensitivity over a wide range of cell sizes in a limited setting (a portable device powered by a battery power, <5 V), a non-inverting preamplifier with a feedback capacitor was adopted, which amplifies only transient potential change. The enhanced sensitivity by the AC gain extended the measurement range from 6-15 mu m to 4-20 mu m. The functionality of the prototypes was evaluated by gauging size and concentration of a mixture of microbeads (6, 10, 15 mu m) as well as diverse cancer cells spiked in diluted blood. The measurement results were validated with the data obtained from FACS (fluorescence activated cell sorting). (C) 2015 Elsevier B.V. All rights reserved. -
dc.identifier.bibliographicCitation SENSORS AND ACTUATORS B-CHEMICAL, v.213, pp.375 - 381 -
dc.identifier.doi 10.1016/j.snb.2015.02.107 -
dc.identifier.issn 0925-4005 -
dc.identifier.scopusid 2-s2.0-84924813758 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/12313 -
dc.identifier.url http://www.sciencedirect.com/science/article/pii/S0925400515002920 -
dc.identifier.wosid 000352152500049 -
dc.language 영어 -
dc.publisher ELSEVIER SCIENCE SA -
dc.title Portable Coulter counter with vertical through-holes for high-throughput applications -
dc.type Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.