File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

방인철

Bang, In Cheol
Nuclear Thermal Hydraulics and Reactor Safety Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 114 -
dc.citation.number 6 -
dc.citation.startPage 109 -
dc.citation.title 한국유체기계학회 논문집 -
dc.citation.volume 17 -
dc.contributor.author Jeong, Yeong Shin -
dc.contributor.author Kim, Kyung Mo -
dc.contributor.author Kim, In Guk -
dc.contributor.author Bang, In Cheol -
dc.date.accessioned 2023-12-22T01:47:41Z -
dc.date.available 2023-12-22T01:47:41Z -
dc.date.created 2015-07-03 -
dc.date.issued 2014-12 -
dc.description.abstract After the Fukushima accident in 2011, it was revealed that nuclear power plant has the vulnerability to SBO accident and its extension situation without sufficient cooling of reactor core resulting core meltdown and radioactive material release even after reactor shutdown. Many safety systems had been developed like PAFS, hybrid SIT, and relocation of RPV and IRWST as a part of steps for the Fukushima accident, however, their applications have limitation in the situation that supply of feedwater into reactor is impossible due to high pressure inside reactor pressure vessel. The concept of hybrid heat pipe with control rod is introduced for breaking through the limitation. Hybrid heat pipe with control rod is the passive decay heat removal system in core, which has the abilities of reactor shutdown as control rod as well as decay heat removal as heat pipe. For evaluating the cooling performance hybrid heat pipe, a commercial CFD code, ANSYS-CFX was used. First, for validating CFD results, numerical results and experimental results with same geometry and fluid conditions were compared to a tube type heat pipe resulting in a resonable agreement between them. After that, wall temperature and thermal resistances of 2 design concepts of hybrid heat pipe were analyzed about various heat inputs. For unit length, hybrid heat pipe with a tube type of B4C pellet has a decreasing tendency of thermal resistance, on the other hand, hybrid heat pipe with an annular type B4C pellet has an increasing tendency as heat input increases. -
dc.identifier.bibliographicCitation 한국유체기계학회 논문집, v.17, no.6, pp.109 - 114 -
dc.identifier.issn 2287-9706 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/11964 -
dc.language 한국어 -
dc.publisher 한국유체기계학회 -
dc.title 원자로 제어봉과 결합된 하이브리드 히트파이프의 CFD 해석 -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.identifier.kciid ART001932254 -
dc.description.journalRegisteredClass kci -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.