File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

조재원

Cho, Jaeweon
Sense Laboratory
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 81 -
dc.citation.number 1-2 -
dc.citation.startPage 71 -
dc.citation.title ENVIRONMENTAL MONITORING AND ASSESSMENT -
dc.citation.volume 70 -
dc.contributor.author Gu, Man Bock -
dc.contributor.author Kim, Byoung Chan -
dc.contributor.author Cho, Jaeweon -
dc.contributor.author Hansen, Peter D. -
dc.date.accessioned 2023-12-22T11:43:32Z -
dc.date.available 2023-12-22T11:43:32Z -
dc.date.created 2015-06-30 -
dc.date.issued 2001-07 -
dc.description.abstract Toxicity monitoring of field water samples was performed using a novel multi-channel two-stage mini-bioreactor system and genetically engineered bioluminescent bacteria for the continuous monitoring and classification of the toxicity present in the samples. The toxicity of various samples spiked with known endocrine disrupting chemicals and phenol was also investigated for system characterization. The field samples used in this study were obtained from two different sites on a monthly basis - from a drinking water treatment plant, referred to as site N, and from a stream near a dam which is currently being constructed, referred to as site T. These samples were either pumped or injected into the second mini-bioreactors to initiate the toxicity test. Most of the samples did not show any specific toxicity. However, one sample showed to have, based upon the detection results, and was deemed toxic. The samples spiked with phenol showed possible responses in the DPD2540 and TV1061 channels, indicating the occurrence of both membrane and protein damage due to phenol. In the tests using an endocrine disrupting chemical, bisphenol A, DNA damage was detected in the DPD2794 channel with a concentration of 2 ppm. Finally, a simple but novel early warning protocol that can be used in a drinking water reservoir and a suspected place where effluents of toxic materials enter the water sourse was suggested with a schematic diagram. In conclusion, this system showed good feasibility for use as a toxicity monitoring system in the field and as an early warning system, indicating if effluents are toxic -
dc.identifier.bibliographicCitation ENVIRONMENTAL MONITORING AND ASSESSMENT, v.70, no.1-2, pp.71 - 81 -
dc.identifier.doi 10.1023/A:1010612727587 -
dc.identifier.issn 0167-6369 -
dc.identifier.scopusid 2-s2.0-0034927010 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/11936 -
dc.identifier.wosid 000169619100007 -
dc.language 영어 -
dc.publisher SPRINGER -
dc.title The continuous monitoring of field water samples with a novel multi-channel two-stage mini-bioreactor system -
dc.type Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.