File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

조재원

Cho, Jaeweon
Sense Laboratory
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 238 -
dc.citation.number 1-2 -
dc.citation.startPage 232 -
dc.citation.title JOURNAL OF MEMBRANE SCIENCE -
dc.citation.volume 278 -
dc.contributor.author Shon, HK -
dc.contributor.author Vigneswaran, S -
dc.contributor.author Kim, IS -
dc.contributor.author Cho, Jaeweon -
dc.contributor.author Ngo, HH -
dc.date.accessioned 2023-12-22T09:44:59Z -
dc.date.available 2023-12-22T09:44:59Z -
dc.date.created 2015-07-01 -
dc.date.issued 2006-07 -
dc.description.abstract Membrane fouling caused by hydrophobic (HP), transphilic (TP), and hydrophilic (HL) fractions in biologically treated sewage effluent (BTSE) are still not well understood. Some researches reported that the HP fraction (humic substances) were the major problem; other studies indicated that the HL fraction (polysacchrides) were the main causes for severe fouling in membrane filtration. Hence, in this study, a detailed ultrafilter experiments were conducted with the HP, TP, and HL fractions to study the membrane fouling. The ultrafiltration (UF) removed 67.4%, 52.9%, and 19.7% of HP, TP, and HL fractions, respectively. High removal of the HP fraction is due to relatively high MW of organic matter in the HP fraction and the interaction between the HP fraction and membrane surface. The flux decline with the HP fraction was high compared with the TP and HL fractions. The membrane fouled with different fractions was characterized in terms of functional groups, zeta potential, foulant concentration, and contact angle. (c) 2005 Elsevier B.V. All rights reserved -
dc.identifier.bibliographicCitation JOURNAL OF MEMBRANE SCIENCE, v.278, no.1-2, pp.232 - 238 -
dc.identifier.doi 10.1016/j.memsci.2005.11.006 -
dc.identifier.issn 0376-7388 -
dc.identifier.scopusid 2-s2.0-33646893043 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/11779 -
dc.identifier.url http://www.sciencedirect.com/science/article/pii/S0376738805008124 -
dc.identifier.wosid 000238409300027 -
dc.language 영어 -
dc.publisher ELSEVIER SCIENCE BV -
dc.title Fouling of ultrafiltration membrane by effluent organic matter: A detailed characterization using different organic fractions in wastewater -
dc.type Article -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor biologically treated sewage effluent -
dc.subject.keywordAuthor effluent organic matter -
dc.subject.keywordAuthor fraction -
dc.subject.keywordAuthor fouling -
dc.subject.keywordAuthor hydrophobic -
dc.subject.keywordAuthor hydrophilic -
dc.subject.keywordAuthor membrane characterization -
dc.subject.keywordAuthor transphilic -
dc.subject.keywordAuthor ultrafiltration -
dc.subject.keywordPlus UF MEMBRANES -
dc.subject.keywordPlus SURFACE-WATER -
dc.subject.keywordPlus NANOFILTRATION -
dc.subject.keywordPlus NOM -
dc.subject.keywordPlus FILTRATION -
dc.subject.keywordPlus REJECTION -
dc.subject.keywordPlus FOULANTS -
dc.subject.keywordPlus NF -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.