File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

조재원

Cho, Jaeweon
Sense Laboratory
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 94 -
dc.citation.number 1-3 -
dc.citation.startPage 82 -
dc.citation.title DESALINATION -
dc.citation.volume 245 -
dc.contributor.author Nguyen, Cuong Manh -
dc.contributor.author Bang, Sunbaek -
dc.contributor.author Cho, Jaeweon -
dc.contributor.author Kim, Kyoung-Woong -
dc.date.accessioned 2023-12-22T07:40:17Z -
dc.date.available 2023-12-22T07:40:17Z -
dc.date.created 2015-07-01 -
dc.date.issued 2009-09 -
dc.description.abstract The removal of arsenic by a commercial nanofiltration membrane was evaluated with respect to the performance and mechanism. The important membrane properties governing the separation of arsenic, such as molecular weight cut-off (MWCO), electrokinetic charge and individual salts rejection characteristics, were determined. The mechanisms of arsenic rejection were directly investigated by measuring the effects of the initial arsenic concentration, arsenic speciation and various electrolytes on the removal of arsenic. Arsenate [As(V)] was rejected at a much higher rate than arsenite [As(III)], which resulted from the dominance of Donnan exclusion over steric exclusion in controlling the arsenic removal capacity of the membrane. In addition, the rejection of monovalent As(V) was enhanced by the presence of Cl-, but reduced by the presence of SO42- due to mutual interactions between anions. Subsequently, the functionalities of Donnan exclusion and mutual ions interactions were validated by testing the removal of arsenic from synthetic water (1 mN NaHCO3 + 10 mN NaCl) over a wide pH range: 4 to 10. With initial As(V) and As(III) concentrations of 50 mu g l(-1), the removal of As(V) increased with increasing pH over the entire range, while that of As(III) significantly increased over the pH range 8 to 10. The arsenic rejection efficiency of the membrane was also evaluated using the synthetic water. Approximately 89-96% of As(V) was removed at pH 7, whereas 44-41% of As (III) was rejected from feed solutions containing 20, 50, 70 and 100 mu g l(-1) As(III) and As(V). In addition, the arsenic separation efficiency increased by less than 3% with increasing applied pressure from 138 to 552 kPa (20-80 psi) -
dc.identifier.bibliographicCitation DESALINATION, v.245, no.1-3, pp.82 - 94 -
dc.identifier.doi 10.1016/j.desal.2008.04.047 -
dc.identifier.issn 0011-9164 -
dc.identifier.scopusid 2-s2.0-67650708610 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/11740 -
dc.identifier.url http://www.sciencedirect.com/science/article/pii/S0011916409003282 -
dc.identifier.wosid 000269141300008 -
dc.language 영어 -
dc.publisher ELSEVIER SCIENCE BV -
dc.title Performance and mechanism of arsenic removal from water by a nanofiltration membrane -
dc.type Article -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.