File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

조윤경

Cho, Yoon-Kyoung
FRUITS Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 485 -
dc.citation.number 2 -
dc.citation.startPage 478 -
dc.citation.title LAB ON A CHIP -
dc.citation.volume 15 -
dc.contributor.author Lee, Won Seok -
dc.contributor.author Sunkara, Vijaya -
dc.contributor.author Han, Ja-Ryoung -
dc.contributor.author Park, Yang-Seok -
dc.contributor.author Cho, Yoon-Kyoung -
dc.date.accessioned 2023-12-22T01:44:40Z -
dc.date.available 2023-12-22T01:44:40Z -
dc.date.created 2014-12-30 -
dc.date.issued 2015-01 -
dc.description.abstract ELISA-based devices are promising tools for the detection of low abundant proteins in biological samples. Reductions of the sample volume and assay time as well as full automation are required for their potential use in point-of-care diagnostic applications. Here, we present a highly efficient lab-on-a-disc composed of a TiO2 nanofibrous mat for sensitive detection of serum proteins with a broad dynamic range, with only 10 ampmu;L of whole blood within 30 min. The TiO2 nanofibers provide high specific surface area as well as active functional groups to capture large amounts of antibodies on the surface. In addition, the device offers efficient mixing and washing for improving the signal-to-noise ratio, thus enhancing the overall detection sensitivity. We employ the device for the detection of cardiac biomarkers, C-reactive protein (CRP) and cardiac troponin I (cTnI), spiked in phosphate-buffered saline (PBS) as well as in serum or whole blood. The device exhibited a wide dynamic range of six orders of magnitude from 1 pg mL-1 (~8 fM) to 100 ng mL-1 (~0.8 pM) and a low detection limit of 0.8 pg mL-1 (~6 fM) for CRP spiked in CRP-free serum and a dynamic range of 10 pg mL-1 (~0.4 pM) to 100 ng mL-1 (~4 nM) with a detection limit of 37 pg mL-1 (~1.5 pM) for cTnI spiked in whole blood. -
dc.identifier.bibliographicCitation LAB ON A CHIP, v.15, no.2, pp.478 - 485 -
dc.identifier.doi 10.1039/c4lc00900b -
dc.identifier.issn 1473-0197 -
dc.identifier.scopusid 2-s2.0-84918772845 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/10042 -
dc.identifier.url https://pubs.rsc.org/en/content/articlelanding/2015/LC/C4LC00900B#!divAbstract -
dc.identifier.wosid 000346477500012 -
dc.language 영어 -
dc.publisher ROYAL SOC CHEMISTRY -
dc.title Electrospun TiO2 nanofiber integrated lab-on-a-disc for ultrasensitive protein detection from whole blood -
dc.type Article -
dc.description.isOpenAccess TRUE -
dc.relation.journalWebOfScienceCategory Biochemical Research Methods; Chemistry, Multidisciplinary; Chemistry, Analytical; Nanoscience & Nanotechnology -
dc.relation.journalResearchArea Biochemistry & Molecular Biology; Chemistry; Science & Technology - Other Topics -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordPlus NANOTUBES -
dc.subject.keywordPlus NANOMATERIALS -
dc.subject.keywordPlus IMMUNOASSAYS -
dc.subject.keywordPlus SUBSTRATE -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.