File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

정모세

Chung, Moses
Intense Beam and Accelerator Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.number 3 -
dc.citation.title JOURNAL OF INSTRUMENTATION -
dc.citation.volume 19 -
dc.contributor.author Arutunian, S. G. -
dc.contributor.author Harutyunyan, G. S. -
dc.contributor.author Lazarev, L. M. -
dc.contributor.author Margaryan, A. V. -
dc.contributor.author Manukyan, N. M. -
dc.contributor.author Lazareva, E. G. -
dc.contributor.author Mirzoyan, G. V. -
dc.contributor.author Gevorgyan, R. S. -
dc.contributor.author Chung, M. -
dc.contributor.author Korzhik, M. V. -
dc.date.accessioned 2024-05-03T10:35:28Z -
dc.date.available 2024-05-03T10:35:28Z -
dc.date.created 2024-04-23 -
dc.date.issued 2024-03 -
dc.description.abstract In the process of irradiation of materials by fluxes of heavy particles (protons, neutrons, alpha particles), damage to material structure is often observed. As a result of the accumulation of such damages, there is a subsequent change in the properties of materials, in particular, its embrittlement and hardening. Monitoring of the embrittlement process is important for nuclear reactor vessels exposed to high neutron fluxes. In this work, to observe the effect of heavy irradiation particles on the mechanical properties of metals, we propose to use vibrating wire resonators, in which the natural frequency of oscillations of the wire strongly depends on its tension. The change in the elastic characteristics of the wire alters the value of the natural frequency of wire oscillations. The natural oscillations are generated by a special circuit. Preliminary experiments to study the embrittlement effect of a stretched wire are performed by heating the wire with an electric current. In the case of short pulses, a significant increase in frequency is achieved, which is explained by the process of hardening of the material as a result of the thermal impact on the wire (rapid heating and cooling). -
dc.identifier.bibliographicCitation JOURNAL OF INSTRUMENTATION, v.19, no.3 -
dc.identifier.doi 10.1088/1748-0221/19/03/C03046 -
dc.identifier.issn 1748-0221 -
dc.identifier.scopusid 2-s2.0-85188292491 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/82296 -
dc.identifier.wosid 001189711800001 -
dc.language 영어 -
dc.publisher IOP Publishing Ltd -
dc.title Metal wire embrittlement monitoring by the measurement of wire oscillation frequency -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Instruments & Instrumentation -
dc.relation.journalResearchArea Instruments & Instrumentation -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Instrumentation for neutron sources -
dc.subject.keywordAuthor Radiation damage monitoring systems -
dc.subject.keywordAuthor Neutron detectors (cold -
dc.subject.keywordAuthor thermal -
dc.subject.keywordAuthor fast neutrons) -

qrcode