File Download

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

이승걸

Lee, Seung Geol
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Liquid-metal-based three-dimensional microelectrode arrays integrated with implantable ultrathin retinal prosthesis for vision restoration

Author(s)
Chung, Won GiJang, JiukCui, GangLee, SanghoonJeong, HanKang, HaisuSeo, HunkyuKim, SuminKim, EnjiLee, JunwonLee, Seung GeolByeon, Suk HoPark, Jang-Ung
Issued Date
2024-01
DOI
10.1038/s41565-023-01587-w
URI
https://scholarworks.unist.ac.kr/handle/201301/81673
Citation
NATURE NANOTECHNOLOGY
Abstract
Electronic retinal prostheses for stimulating retinal neurons are promising for vision restoration. However, the rigid electrodes of conventional retinal implants can inflict damage on the soft retina tissue. They also have limited selectivity due to their poor proximity to target cells in the degenerative retina. Here we present a soft artificial retina (thickness, 10 mu m) where flexible ultrathin photosensitive transistors are integrated with three-dimensional stimulation electrodes of eutectic gallium-indium alloy. Platinum nanoclusters locally coated only on the tip of these three-dimensional liquid-metal electrodes show advantages in reducing the impedance of the stimulation electrodes. These microelectrodes can enhance the proximity to the target retinal ganglion cells and provide effective charge injections (72.84 mC cm-2) to elicit neural responses in the retina. Their low Young's modulus (234 kPa), owing to their liquid form, can minimize damage to the retina. Furthermore, we used an unsupervised machine learning approach to effectively identify the evoked spikes to grade neural activities within the retinal ganglion cells. Results from in vivo experiments on a retinal degeneration mouse model reveal that the spatiotemporal distribution of neural responses on their retina can be mapped under selective localized illumination areas of light, suggesting the restoration of their vision. A soft artificial retina with flexible phototransistors and three-dimensional liquid-metal microelectrodes is used to enhance proximity to retinal ganglion cells and minimize damage to soft tissue as well as improve charge injection for vision restoration in retinal degenerative in vivo models.
Publisher
NATURE PORTFOLIO
ISSN
1748-3387
Keyword
STIMULATIONIMPEDANCE

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.