There are no files associated with this item.
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.citation.endPage | 1425 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 1413 | - |
dc.citation.title | IEEE TRANSACTIONS ON MEDICAL IMAGING | - |
dc.citation.volume | 31 | - |
dc.contributor.author | Chun, Se Young | - |
dc.contributor.author | Fessler, Jeffrey A. | - |
dc.date.accessioned | 2023-12-22T05:06:42Z | - |
dc.date.available | 2023-12-22T05:06:42Z | - |
dc.date.created | 2014-10-29 | - |
dc.date.issued | 2012-07 | - |
dc.description.abstract | Many motion-compensated image reconstruction (MCIR) methods have been proposed to correct for subject motion in medical imaging. MCIR methods incorporate motion models to improve image quality by reducing motion artifacts and noise. This paper analyzes the spatial resolution properties of MCIR methods and shows that nonrigid local motion can lead to nonuniform and anisotropic spatial resolution for conventional quadratic regularizers. This undesirable property is akin to the known effects of interactions between heteroscedastic log-likelihoods (e.g., Poisson likelihood) and quadratic regularizers. This effect may lead to quantification errors in small or narrow structures (such as small lesions or rings) of reconstructed images. This paper proposes novel spatial regularization design methods for three different MCIR methods that account for known nonrigid motion. We develop MCIR regularization designs that provide approximately uniform and isotropic spatial resolution and that match a user-specified target spatial resolution. Two-dimensional PET simulations demonstrate the performance and benefits of the proposed spatial regularization design methods. | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON MEDICAL IMAGING, v.31, no.7, pp.1413 - 1425 | - |
dc.identifier.doi | 10.1109/TMI.2012.2192133 | - |
dc.identifier.issn | 0278-0062 | - |
dc.identifier.scopusid | 2-s2.0-84863424615 | - |
dc.identifier.uri | https://scholarworks.unist.ac.kr/handle/201301/7985 | - |
dc.identifier.url | http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84863424615 | - |
dc.identifier.wosid | 000305898500008 | - |
dc.language | 영어 | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.title | Spatial Resolution Properties of Motion-Compensated Tomographic Image Reconstruction Methods | - |
dc.type | Article | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordAuthor | Isotropic and uniform spatial resolution | - |
dc.subject.keywordAuthor | motion-compensated image reconstruction |
- |
dc.subject.keywordAuthor | nonrigid motion | - |
dc.subject.keywordAuthor | quadratic regularization | - |
dc.subject.keywordAuthor | regularization design | - |
dc.subject.keywordPlus | EMISSION-TOMOGRAPHY | - |
dc.subject.keywordPlus | DEFORMABLE REGISTRATION | - |
dc.subject.keywordPlus | MAXIMUM-LIKELIHOOD | - |
dc.subject.keywordPlus | NOISE PROPERTIES |
- |
dc.subject.keywordPlus | OPTICAL-FLOW | - |
dc.subject.keywordPlus | PET IMAGES | - |
dc.subject.keywordPlus | GATED PET | - |
dc.subject.keywordPlus | CT SCANS | - |
dc.subject.keywordPlus | 3-D PET | - |
dc.subject.keywordPlus | SUPERRESOLUTION | - |
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Tel : 052-217-1404 / Email : scholarworks@unist.ac.kr
Copyright (c) 2023 by UNIST LIBRARY. All rights reserved.
ScholarWorks@UNIST was established as an OAK Project for the National Library of Korea.