File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

이창영

Lee, Chang Young
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 2045 -
dc.citation.number 11 -
dc.citation.startPage 2037 -
dc.citation.title LAB ON A CHIP -
dc.citation.volume 12 -
dc.contributor.author Zhong, Ming -
dc.contributor.author Lee, Chang Young -
dc.contributor.author Croushore, Callie A. -
dc.contributor.author Sweedler, Jonathan V. -
dc.date.accessioned 2023-12-22T05:09:47Z -
dc.date.available 2023-12-22T05:09:47Z -
dc.date.created 2014-10-07 -
dc.date.issued 2012-05 -
dc.description.abstract Microfluidic technology allows the manipulation of mass-limited samples and when used with cultured cells, enables control of the extracellular microenvironment, making it well suited for studying neurons and their response to environmental perturbations. While matrix-assisted laser desorption/ ionization (MALDI) mass spectrometry (MS) provides for off-line coupling to microfluidic devices for characterizing small-volume extracellular releasates, performing quantitative studies with MALDI is challenging. Here we describe a label-free absolute quantitation approach for microfluidic devices. We optimize device fabrication to prevent analyte losses before measurement and then incorporate a substrate that collects the analytes as they flow through a collection channel. Following collection, the channel is interrogated using MS imaging. Rather than quantifying the sample present via MS peak height, the length of the channel containing appreciable analyte signal is used as a measure of analyte amount. A linear relationship between peptide amount and band length is suggested by modeling the adsorption process and this relationship is validated using two neuropeptides, acidic peptide (AP) and α-bag cell peptide [1-9] (αBCP). The variance of length measurement, defined as the ratio of standard error to mean value, is as low as 3% between devices. The limit of detection (LOD) of our system is 600 fmol for AP and 400 fmol for αBCP. Using appropriate calibrations, we determined that an individual Aplysia bag cell neuron secretes 0.15 ± 0.03 pmol of AP and 0.13 ± 0.06 pmol of αBCP after being stimulated with elevated KCl. This quantitation approach is robust, does not require labeling, and is well suited for miniaturized off-line characterization from microfluidic devices. -
dc.identifier.bibliographicCitation LAB ON A CHIP, v.12, no.11, pp.2037 - 2045 -
dc.identifier.doi 10.1039/c2lc21085a -
dc.identifier.issn 1473-0197 -
dc.identifier.scopusid 2-s2.0-84862211299 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/6950 -
dc.identifier.url http://pubs.rsc.org/en/Content/ArticleLanding/2012/LC/c2lc21085a#!divAbstract -
dc.identifier.wosid 000304247900017 -
dc.language 영어 -
dc.publisher ROYAL SOC CHEMISTRY -
dc.title Label-free quantitation of peptide release from neurons in a microfluidic device with mass spectrometry imaging -
dc.type Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordPlus MALDI-TOF MS -
dc.subject.keywordPlus LASER-DESORPTION/IONIZATION-TIME -
dc.subject.keywordPlus BAG CELL NEURONS -
dc.subject.keywordPlus CAPILLARY-ELECTROPHORESIS -
dc.subject.keywordPlus NEUROENDOCRINE CELLS -
dc.subject.keywordPlus GLYCOL) MONOLAYERS -
dc.subject.keywordPlus HORMONE-SECRETION -
dc.subject.keywordPlus HIGH-THROUGHPUT -
dc.subject.keywordPlus SOLID-SURFACES -
dc.subject.keywordPlus SINGLE-CELL -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.