File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

임한권

Lim, Hankwon
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 389 -
dc.citation.number 4 -
dc.citation.startPage 373 -
dc.citation.title KOREA-AUSTRALIA RHEOLOGY JOURNAL -
dc.citation.volume 35 -
dc.contributor.author Ullah, Minhaj -
dc.contributor.author Cheema, Taqi Ahmad -
dc.contributor.author Aleksey, Ni -
dc.contributor.author Jamil, Muhammad -
dc.contributor.author Ahmad, Faiq -
dc.contributor.author Lim, Hankwon -
dc.date.accessioned 2023-12-14T17:10:24Z -
dc.date.available 2023-12-14T17:10:24Z -
dc.date.created 2023-12-04 -
dc.date.issued 2023-11 -
dc.description.abstract The double-lumen cannula (DLC) is the most critical component of extracorporeal membrane oxygenation (ECMO) because of its narrow cross-section, thereby developing the highest shear stress in the entire ECMO circuit. To measure blood damage in a DLC, the Eulerian approach is generally used without contemplating exposure time or history of blood exposure to shear stresses. Alternatively, Lagrangian approach has also been recently employed for a Newtonian blood flow through a DLC, thereby leaving a research gap on the impact of variable shear rate in case of non-Newtonian blood flow. In the present study, the hemodynamic performance of DLC is investigated using different non-Newtonian models by applying Lagrangian approach. Moreover, the motion of RBC was tracked inside the cannula to predict its behavior during the motion. The results showed that the return lumen had higher pressure, velocity, and shear stress values than other parts of the DLC. In addition, recirculation was observed due to the mixing of blood coming from different inlets and found increase with increasing flow rate of blood. Moreover, it was found that the blood damage increased with increasing flow rate. There was more blood damage in the Newtonian model than in the other non-Newtonian models at higher flow rates. However, the Carreau model showed more blood damage at lower flow rates than the other models. The Cross model showed DLC's higher efficacy in delivering oxygenated blood to the tricuspid outlet because it showed the least blood damage among all other models. It was also concluded that the efficacy of the DLC to deliver oxygenated blood to the tricuspid outlet decreases with increasing blood flow rate. -
dc.identifier.bibliographicCitation KOREA-AUSTRALIA RHEOLOGY JOURNAL, v.35, no.4, pp.373 - 389 -
dc.identifier.doi 10.1007/s13367-023-00073-y -
dc.identifier.issn 1226-119X -
dc.identifier.scopusid 2-s2.0-85173529812 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/66430 -
dc.identifier.wosid 001094646600001 -
dc.language 영어 -
dc.publisher KOREAN SOC RHEOLOGY -
dc.title Rheological investigation of neonatal double-lumen cannula with and without deformable erythrocytes -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Mechanics; Polymer Science -
dc.relation.journalResearchArea Mechanics; Polymer Science -
dc.type.docType Article; Early Access -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.description.journalRegisteredClass kci -
dc.subject.keywordAuthor Extracorporeal membrane oxygenation (ECMO) -
dc.subject.keywordAuthor Hemodynamic performance -
dc.subject.keywordAuthor Rheological performance -
dc.subject.keywordAuthor Double-lumen cannula (DLC) -
dc.subject.keywordAuthor Blood damage -
dc.subject.keywordPlus BLOOD-FLOW -
dc.subject.keywordPlus OXYGENATION -
dc.subject.keywordPlus VISCOSITY -
dc.subject.keywordPlus ECMO -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.