File Download

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.number 9 -
dc.citation.startPage e0291712 -
dc.citation.title PLOS ONE -
dc.citation.volume 18 -
dc.contributor.author Jung, Seongmoon -
dc.contributor.author Kim, Bitbyeol -
dc.contributor.author Lee, Sung Young -
dc.contributor.author Chang, Won Ick -
dc.contributor.author Son, Jaeman -
dc.contributor.author Park, Jong Min -
dc.contributor.author Choi, Chang Heon -
dc.contributor.author Lee, Joo Ho -
dc.contributor.author Wu, Hong-Gyun -
dc.contributor.author Kim, Jung-in -
dc.contributor.author Kim, Jin Ho -
dc.date.accessioned 2023-12-21T11:43:41Z -
dc.date.available 2023-12-21T11:43:41Z -
dc.date.created 2023-10-26 -
dc.date.issued 2023-09 -
dc.description.abstract This study aimed to assess the performance of a tongue-positioning device in interfractional tongue position reproducibility by cone-beam computed tomography (CBCT). Fifty-two patients treated with radiation therapy (RT) while using a tongue positioning device were included in the study. All patients were treated with 28 or 30 fractions using the volumetric modulated arc therapy technique. CBCT images were acquired at the 1(st), 7(th), 11(th), 15(th), 19(th), 23(th), and 27(th) fractions. Tongues on planning computed tomography (pCT) and CBCT images were contoured in the treatment planning system. Geometric differences in the tongue between pCT and CBCT were assessed by the Dice similarity coefficient (DSC) and averaged Hausdorff distance (AHD). Two-dimensional in vivo measurements using radiochromic films were performed in 13 patients once a week during sessions. The planned dose distributions were compared with the measured dose distributions using gamma analysis with criteria of 3%/3 mm. In all patients, the mean DSC at the 1(st) fraction (pCT versus 1st CBCT) was 0.80 while the mean DSC at the 27(th) fraction (pCT versus 27th CBCT) was 0.77 with statistical significance (p-value = 0.015). There was no statistically significant difference in DSC between the 1st fraction and any other fraction, except for the 27(th) fraction. There was statistically significant difference in AHD between the 1st fraction and the 19th, 23(th), and 27(th) fractions (p-value < 0.05). In vivo measurements showed an average gamma passing rate of 90.54%. There was no significant difference between measurements at the 1(st )week and those at other weeks. The tongue geometry during RT was compared between pCT and CBCT. In conclusion, the novel tongue-positioning device was found to minimize interfractional variations in position and shape of the tongue. -
dc.identifier.bibliographicCitation PLOS ONE, v.18, no.9, pp.e0291712 -
dc.identifier.doi 10.1371/journal.pone.0291712 -
dc.identifier.issn 1932-6203 -
dc.identifier.scopusid 2-s2.0-85171960977 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/66052 -
dc.identifier.wosid 001077380700059 -
dc.language 영어 -
dc.publisher PUBLIC LIBRARY SCIENCE -
dc.title Novel tongue-positioning device to reduce tongue motions during radiation therapy for head and neck cancer: Geometric and dosimetric evaluation -
dc.type Article -
dc.description.isOpenAccess TRUE -
dc.relation.journalWebOfScienceCategory Multidisciplinary Sciences -
dc.relation.journalResearchArea Science & Technology - Other Topics -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordPlus ORAL STENTS -
dc.subject.keywordPlus RADIOTHERAPY -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.