File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

박수진

Park, Soojin
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 2642 -
dc.citation.number 9 -
dc.citation.startPage 2638 -
dc.citation.title ANALYTICAL CHEMISTRY -
dc.citation.volume 76 -
dc.contributor.author Im, K -
dc.contributor.author Park, Soojin -
dc.contributor.author Cho, D -
dc.contributor.author Chang, T -
dc.contributor.author Lee, K -
dc.contributor.author Choi, N -
dc.date.accessioned 2023-12-22T11:06:29Z -
dc.date.available 2023-12-22T11:06:29Z -
dc.date.created 2014-09-26 -
dc.date.issued 2004-05 -
dc.description.abstract Temperature gradient interaction chromatography (TGIC) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) were applied for the characterization of highly branched polystyrenes (PS) prepared by linking living polystyryl anions using 4-chlorodimethylsilylstyrene. Reversed-phase (RP)-TGIC showed an unexpectedly high resolution according to the number of branches despite significant overlap of the molecular weight as confirmed by MALDI-TOF MS. The enhancement of the resolution is ascribed to the contribution of the nonpolar groups in the branched PS: the dimethylsilyl groups in the branching unit as well as the see-butyl initiator groups. As the number of branches increases, the number of nonpolar groups increases, which in turn increases the RP-TGIC retention synergistically with increasing molecular weight. In contrast, a poorer resolution was found in normal-phase-TGIC, in which the nonpolar groups reduce the retention. The resolution in RP-TGIC appears superior to that of liquid chromatography at the chromatographic critical condition (LCCC) of PS. It is seemingly due to the synergistic contribution of the incremental PS molecular weight to the functionality in the branched PS in RP-TGIC while only the functionality contributes to the separation in LCCC. This type of resolution enhancement could be utilized efficiently for the analysis of highly branched polymers such as dendrimers or hyperbranched polymers. -
dc.identifier.bibliographicCitation ANALYTICAL CHEMISTRY, v.76, no.9, pp.2638 - 2642 -
dc.identifier.doi 10.1021/ac035506p -
dc.identifier.issn 0003-2700 -
dc.identifier.scopusid 2-s2.0-2342507760 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/6556 -
dc.identifier.url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=2342507760 -
dc.identifier.wosid 000221205900039 -
dc.language 영어 -
dc.publisher AMER CHEMICAL SOC -
dc.title HPLC and MALDI-TOF MS analysis of highly branched polystyrene: Resolution enhancement by branching -
dc.type Article -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.