File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 68 -
dc.citation.startPage 65 -
dc.citation.title NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS -
dc.citation.volume 541 -
dc.contributor.author Lee, K. B. -
dc.contributor.author Ham, C. -
dc.contributor.author Tshoo, K. -
dc.contributor.author Hong, S. W. -
dc.contributor.author Moon, D. -
dc.contributor.author Lee, S. -
dc.contributor.author Pyeun, S. -
dc.contributor.author Akers, C. -
dc.contributor.author Kwag, M. S. -
dc.contributor.author Kim, M. -
dc.contributor.author Kim, J. C. -
dc.contributor.author Kwak, D. -
dc.contributor.author Shin, T. -
dc.date.accessioned 2023-12-21T11:46:49Z -
dc.date.available 2023-12-21T11:46:49Z -
dc.date.created 2023-09-13 -
dc.date.issued 2023-08 -
dc.description.abstract The Nuclear Data Production System (NDPS) at RAON has been built to produce nuclear data generated by the reactions induced by neutrons of tens of MeV. For the neutron Time-Of-Flight (TOF) measurement, neutron monitoring detectors based on a gas-filled Parallel Plate Avalanche Counter (PPAC) and a MICRO-MEsh-GASeous (MICROMEGAS) detector have been developed by the Rare Isotope Science Project (RISP) and Sungkyunkwan University (SKKU). These detectors have a neutron converter with a thin 232Th layer, which produces fission products due to fast neutrons. The PPAC achieved a 1 ns FWHM time resolution in a test with an 241Am ������ source and also showed good performance when tested with fast neutrons generated by a 45 MeV proton beam through the 9Be(p, n)9B reaction. Additionally, EJ-301, liquid scintillation detectors are assembled for the measurement of neutron flux with pulse shape discrimination capability. Slow charge signals as well as fast timing signals from the detectors will be processed for particle identification by a data acquisition (DAQ) system, located at a separate control room through 30 m long cables. Development of the detection system and the test results will be reported together with the on-site assembly status. -
dc.identifier.bibliographicCitation NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, v.541, pp.65 - 68 -
dc.identifier.doi 10.1016/j.nimb.2023.05.019 -
dc.identifier.issn 0168-583X -
dc.identifier.scopusid 2-s2.0-85159049988 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/65530 -
dc.identifier.wosid 001053141500001 -
dc.language 영어 -
dc.publisher ELSEVIER -
dc.title Development of neutron detection systems at the NDPS of RAON -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Instruments & Instrumentation; Nuclear Science & Technology; Physics, Atomic, Molecular & Chemical; Physics, Nuclear -
dc.relation.journalResearchArea Instruments & Instrumentation; Nuclear Science & Technology; Physics -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Rare isotope science project -
dc.subject.keywordAuthor NDPS -
dc.subject.keywordAuthor Neutron detector -
dc.subject.keywordAuthor DAQ -
dc.subject.keywordPlus CROSS-SECTION -
dc.subject.keywordPlus PPAC -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.