File Download

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

이창영

Lee, Chang Young
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.number 15 -
dc.citation.startPage 2199 -
dc.citation.title NANOMATERIALS -
dc.citation.volume 13 -
dc.contributor.author Lee, Seongwoo -
dc.contributor.author Park, Sanghwan -
dc.contributor.author Lim, Seongyeop -
dc.contributor.author Lee, Cheongha -
dc.contributor.author Lee, Chang Young -
dc.date.accessioned 2023-12-21T11:47:25Z -
dc.date.available 2023-12-21T11:47:25Z -
dc.date.created 2023-09-05 -
dc.date.issued 2023-08 -
dc.description.abstract Toxic industrial chemicals (TICs), when accidentally released into the workplace or environment, often form a gaseous mixture that complicates detection and mitigation measures. However, most of the existing gas sensors are unsuitable for detecting such mixtures. In this study, we demonstrated the detection and identification of gaseous mixtures of TICs using a chemiresistor array of single-walled carbon nanotubes (SWCNTs). The array consists of three SWCNT chemiresistors coated with different molecular/ionic species, achieving a limit of detection (LOD) of 2.2 ppb for ammonia (NH3), 820 ppb for sulfur dioxide (SO2), and 2.4 ppm for ethylene oxide (EtO). By fitting the concentration-dependent sensor responses to an adsorption isotherm, we extracted parameters that characterize each analyte-coating combination, including the proportionality and equilibrium constants for adsorption. Principal component analysis confirmed that the sensor array detected and identified mixtures of two TIC gases: NH3/SO2, NH3/EtO, and SO2/EtO. Exposing the sensor array to three TIC mixtures with various EtO/SO2 ratios at a fixed NH3 concentration showed an excellent correlation between the sensor response and the mixture composition. Additionally, we proposed concentration ranges within which the sensor array can effectively detect the gaseous mixtures. Being highly sensitive and capable of analyzing both individual and mixed TICs, our gas sensor array has great potential for monitoring the safety and environmental effects of industrial chemical processes. -
dc.identifier.bibliographicCitation NANOMATERIALS, v.13, no.15, pp.2199 -
dc.identifier.doi 10.3390/nano13152199 -
dc.identifier.issn 2079-4991 -
dc.identifier.scopusid 2-s2.0-85167681998 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/65310 -
dc.identifier.wosid 001046320900001 -
dc.language 영어 -
dc.publisher MDPI -
dc.title Potential of Carbon Nanotube Chemiresistor Array in Detecting Gas-Phase Mixtures of Toxic Chemical Compounds -
dc.type Article -
dc.description.isOpenAccess TRUE -
dc.relation.journalWebOfScienceCategory Chemistry, Multidisciplinary; Nanoscience & Nanotechnology; Materials Science, Multidisciplinary; Physics, Applied -
dc.relation.journalResearchArea Chemistry; Science & Technology - Other Topics; Materials Science; Physics -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor gas sensor array -
dc.subject.keywordAuthor single-walled carbon nanotubes -
dc.subject.keywordAuthor toxic industrial chemicals -
dc.subject.keywordAuthor adsorption -
dc.subject.keywordPlus SENSOR ARRAY -
dc.subject.keywordPlus ETHYLENE-OXIDE -
dc.subject.keywordPlus ADSORPTION -
dc.subject.keywordPlus SNO2 -
dc.subject.keywordPlus NANOMATERIALS -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.