File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

박현거

Park, Hyeon Keo
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 11 -
dc.citation.number 9 -
dc.citation.startPage 1 -
dc.citation.title PLASMA PHYSICS AND CONTROLLED FUSION -
dc.citation.volume 56 -
dc.contributor.author Lee, Woochang -
dc.contributor.author Yun, Gunsu -
dc.contributor.author Park, Hyeon Keo -
dc.contributor.author Nam, Yoonbum -
dc.contributor.author Seon, C. R. -
dc.date.accessioned 2023-12-22T02:13:18Z -
dc.date.available 2023-12-22T02:13:18Z -
dc.date.created 2014-09-25 -
dc.date.issued 2014-09 -
dc.description.abstract he design of an electron cyclotron emission imaging (ECEI) system for two-dimensional (2D) observation of the magnetohydrodynamical modes in high temperature ITER (from 'International Thermonuclear Experimental Reactor') H-mode-like plasmas (5.3T and 25keV) based on fundamental ordinary mode (O1-mode) and second-harmonic extraordinary mode (X2-mode) measurements is explored conceptually. For studying the spatial resolution in high temperature plasmas, the relativistic broadening and inward shift of the emission layer in the mid-plane are calculated. The radial spatial resolution is significantly degraded in the range R< 5.1m for the O1-mode and in the range R<6.9m for the X2-mode. The region with R<6.5m is inaccessible for X2-mode study. The emission layer width is enlarged in a narrow region of the pedestal due to the magnetic field being modified by the large pressure gradient. The broadening and shift in the poloidal plane are also calculated, to investigate their effects on 2D measurements. The frequency range of electron cyclotron emission measurements is selected to protect the system from stray radiations of the 170GHz electron cyclotron resonance heating source and to avoid harmonic overlap. The frequency ranges of 115-160GHz for the O1-mode and 230-320GHz for the X2-mode provide radial coverage of 5.9 -
dc.identifier.bibliographicCitation PLASMA PHYSICS AND CONTROLLED FUSION, v.56, no.9, pp.1 - 11 -
dc.identifier.doi 10.1088/0741-3335/56/9/095017 -
dc.identifier.issn 0741-3335 -
dc.identifier.scopusid 2-s2.0-84906568849 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/6407 -
dc.identifier.url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84906568849 -
dc.identifier.wosid 000341854100027 -
dc.language 영어 -
dc.publisher IOP PUBLISHING LTD -
dc.title The conceptual design of an electron cyclotron emission imaging system for studying ITER-like high temperature plasmas -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Physics, Fluids & Plasmas -
dc.relation.journalResearchArea Physics -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.