File Download

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

양준모

Yang, Joon Mo
Medical Device and System Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 26181 -
dc.citation.number 15 -
dc.citation.startPage 26169 -
dc.citation.title OPTICS EXPRESS -
dc.citation.volume 30 -
dc.contributor.author Kim, KiSik -
dc.contributor.author Youm, Jin Young -
dc.contributor.author Lee, Eun Hye -
dc.contributor.author Gulenko, Olseksandra -
dc.contributor.author Kim, Minjae -
dc.contributor.author Yoon, Bo Hyun -
dc.contributor.author Jeon, Minji -
dc.contributor.author Kim, Tae Hyo -
dc.contributor.author Ha, Yun-Sok -
dc.contributor.author Yang, Joon Mo -
dc.date.accessioned 2023-12-21T14:06:57Z -
dc.date.available 2023-12-21T14:06:57Z -
dc.date.created 2022-06-17 -
dc.date.issued 2022-07 -
dc.description.abstract Early diagnosis is critical for treating bladder cancer, as this cancer is very aggressive and lethal if detected too late. To address this important clinical issue, a photoacoustic tomography (PAT)-based transabdominal imaging approach was suggested in previous reports, in which its in vivo feasibility was also demonstrated based on a small animal model. However, successful translation of this approach to real clinical settings would be challenging because the human bladder is located at a depth that far exceeds the typical penetration depth of PAT (∼3 cm for in vivo cases). In this study, we developed a tapered catheter-based, transurethral photoacoustic and ultrasonic endoscopic probe with a 2.8 mm outer diameter to investigate whether the well-known benefits of PAT can be harnessed to resolve unmet urological issues, including early diagnosis of bladder cancer. To demonstrate the in vivo imaging capability of the proposed imaging probe, we performed a rabbit model-based urinary system imaging experiment and acquired a 3D microvasculature map distributed in the wall of the urinary system, which is a first in PAT, to the best of our knowledge. We believe that the results strongly support the use of this transurethral imaging approach as a feasible strategy for addressing urological diagnosis issues. -
dc.identifier.bibliographicCitation OPTICS EXPRESS, v.30, no.15, pp.26169 - 26181 -
dc.identifier.doi 10.1364/OE.461855 -
dc.identifier.issn 1094-4087 -
dc.identifier.scopusid 2-s2.0-85140143406 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/58686 -
dc.identifier.url https://opg.optica.org/oe/fulltext.cfm?uri=oe-30-15-26169&id=477751 -
dc.identifier.wosid 000828676200019 -
dc.language 영어 -
dc.publisher Optical Society of America -
dc.title Tapered catheter-based transurethral photoacoustic and ultrasonic endoscopy of the urinary system -
dc.type Article -
dc.description.isOpenAccess TRUE -
dc.relation.journalWebOfScienceCategory Optics -
dc.relation.journalResearchArea Optics -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordPlus OPTICAL COHERENCE TOMOGRAPHY -
dc.subject.keywordPlus BLADDER-CANCER -
dc.subject.keywordPlus PROSTATE -
dc.subject.keywordPlus PROBE -
dc.subject.keywordPlus CYSTOSCOPY -
dc.subject.keywordPlus DESIGN -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.