File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.number 7 -
dc.citation.startPage 2787 -
dc.citation.title SENSORS -
dc.citation.volume 22 -
dc.contributor.author Kim, Young-Joon -
dc.contributor.author Chinnadayyala, Somasekhar R. -
dc.contributor.author Le, Hien T. Ngoc -
dc.contributor.author Cho, Sungbo -
dc.date.accessioned 2023-12-21T14:16:27Z -
dc.date.available 2023-12-21T14:16:27Z -
dc.date.created 2022-04-29 -
dc.date.issued 2022-04 -
dc.description.abstract Miniaturization and wireless continuous glucose monitoring are key factors for the successful management of diabetes. Electrochemical sensors are very versatile and can be easily miniaturized for wireless glucose monitoring. The authors report a microneedle-based enzyme-free electrochemical wireless sensor for painless and continuous glucose monitoring. The microneedles (MNs) fabricated consist of a 3 x 5 sharp and stainless-steel electrode array configuration. Each MN in the 3 x 5 array has 575 mu m x 150 mu m in height and width, respectively. A glucose-catalyzing layer, porous platinum black, was electrochemically deposited on the tips of the MNs by applying a fixed cathodic current of 2.5 mA cm(-2) for a period of 200 s. For the non-interference glucose sensing, the platinum (Pt)-black-coated MN was carefully packaged into a biocompatible ionomer, nafion. The surface morphologies of the bare and modified MNs were studied using field-emission scanning electron microscopy (FESEM) and energy-dispersive X-ray analysis (EDX). The wireless glucose sensor displayed a broad linear range of glucose (1 -> 30 mM), a good sensitivity and higher detection limit of 145.33 mu A mM(-1) cm(-2) and 480 mu M, respectively, with bare AuMN as a counter electrode. However, the wireless device showed an improved sensitivity and enhanced detection limit of 445.75, 165.83 mu A mM(-1) cm(-2) and 268 mu M, respectively, with the Pt-black-modified MN as a counter electrode. The sensor also exhibited a very good response time (2 s) and a limited interference effect on the detection of glucose in the presence of other electroactive oxidizing species, indicating a very fast and interference-free chronoamperometric response. -
dc.identifier.bibliographicCitation SENSORS, v.22, no.7, pp.2787 -
dc.identifier.doi 10.3390/s22072787 -
dc.identifier.issn 1424-8220 -
dc.identifier.scopusid 2-s2.0-85127610005 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/58407 -
dc.identifier.url https://www.mdpi.com/1424-8220/22/7/2787 -
dc.identifier.wosid 000780809800001 -
dc.language 영어 -
dc.publisher MDPI -
dc.title Sensitive Electrochemical Non-Enzymatic Detection of Glucose Based on Wireless Data Transmission -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Chemistry, Analytical; Engineering, Electrical & Electronic; Instruments & Instrumentation -
dc.relation.journalResearchArea Chemistry; Engineering; Instruments & Instrumentation -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor microneedle electrode array -
dc.subject.keywordAuthor continuous glucose monitoring -
dc.subject.keywordAuthor wireless data transmission -
dc.subject.keywordAuthor chronoamperometry -
dc.subject.keywordAuthor platinum black -
dc.subject.keywordAuthor glucose sensor -
dc.subject.keywordPlus SENSOR -
dc.subject.keywordPlus ELECTRODE -
dc.subject.keywordPlus NANOCOMPOSITE -
dc.subject.keywordPlus BIOSENSOR -
dc.subject.keywordPlus ARRAY -
dc.subject.keywordPlus ACID -