File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

김건

Kim, Gun
Smart Materials and Intelligent Structures Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

High-intensity focused ultrasound-induced mechanochemical transduction in synthetic elastomers

Author(s)
Kim, GunLau, Vivian M.Halmes, Abigail J.Oelze, Michael L.Moore, Jeffrey S.Li, King C.
Issued Date
2019-05
DOI
10.1073/pnas.1901047116
URI
https://scholarworks.unist.ac.kr/handle/201301/48614
Fulltext
https://www.pnas.org/content/116/21/10214
Citation
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, v.116, no.21, pp.10214 - 10222
Abstract
While study in the field of polymer mechanochemistry has yielded mechanophores that perform various chemical reactions in response to mechanical stimuli, there is not yet a triggering method compatible with biological systems. Applications such as using mechanoluminescence to generate localized photon flux in vivo for optogenetics would greatly benefit from such an approach. Here we introduce a method of triggering mechanophores by using high-intensity focused ultrasound (HIFU) as a remote energy source to drive the spatially and temporally resolved mechanical-to-chemical transduction of mechanoresponsive polymers. A HIFU setup capable of controlling the excitation pressure, spatial location, and duration of exposure is employed to activate mechanochemical reactions in a cross-linked elastomeric polymer in a noninvasive fashion. One reaction is the chromogenic isomerization of a naphthopyran mechanophore embedded in a polydimethylsiloxane (PDMS) network. Under HIFU irradiation evidence of the mechanochemical transduction is the observation of a reversible color change as expected for the isomerization. The elastomer exhibits this distinguishable color change at the focal spot, depending on ultrasonic exposure conditions. A second reaction is the demonstration that HIFU irradiation successfully triggers a luminescent dioxetane, resulting in localized generation of visible blue light at the focal spot. In contrast to conventional stimuli such as UV light, heat, and uniaxial compression/tension testing, HIFU irradiation provides spatiotemporal control of the mechanochemical activation through targeted but noninvasive ultrasonic energy deposition. Targeted, remote light generation is potentially useful in biomedical applications such as optogenetics where a light source is used to trigger a cellular response.
Publisher
NATL ACAD SCIENCES
ISSN
0027-8424
Keyword (Author)
spatiotemporal controlhigh-intensity focused ultrasoundmechanochromismmechanophoresmechanoluminescence
Keyword
ACOUSTIC RADIATION FORCEDRUG-DELIVERYPOLYMER MECHANOCHEMISTRYCOVALENT BONDSACTIVATIONRELEASE

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.